32
The
installer’s password in units is set to "0000" and must be changed
after installation!
(program P7).
EXAMPLE:
To enter the unit programming function with 2222 installer’s code, press the
"
key
" followed by 1507 (fixed digits) and 2222.
1
5
0
7
2
2
2
2
Upon entering the installer programming, the display will briefly show "
PROGR
"
and the software version number, followed by the P0 program name "
oOpen
".
Programs can be changed using button "2" - up and "8" - down. The displayed
program is selected by pressing the "
Key
" button. Upon entering the desired
program, the display will first show the value of the current setting, only then a
new setting can be entered; the new setting must be confirmed with the "
Key
"
button, or cancelled with the "#" button (if no new value is entered within a few
seconds, unit will automatically exit the installer programming without changing
any setting values).
Exit from the installer function is possible by pressing the "#" key, through the "0"
function (with lock opening) or automatically after approx. 30s of inactivity.
Confirmation of the exit is signalled by a modulated "down" sound signal, and the
display shows the current temperature inside the unit (used to switch the display
heating on).
The installer mode enables resetting (restarting) the unit by pressing buttons 7
and 9 simultaneously.
These programs support both uniphones and video display units.
The following programs are run on the unit:
P0 SERVICE ACTIVATION OF E-LOCK
Open
Maintenance function - verification of E-lock operation and proper opening time.
Selecting the P0 program - "
Open
" - by pressing the "key" button, activates the
E-lock for the time set in P6 and exits the programming function. This program
also disables (if enabled in P5) the function of service uniphone calling from
apartment.