49
Bit1.- Enable further door opening after further door opening after time
[1opn.]
When enabled, this bit causes automatic activation of the E-lock (auto-open) after
the delay time pre-set in P6 when using further door opening or closing the INPUT
on the master unit.
Bit2.- for CDNP5: Enable and disable operation as master unit [2Nad].
This bit is enabled only when operating as a master unit in systems with multiple
units. Enable this bit to detect a busy or short circuited slave unit line.
Bit2.- for CDNP6: Input function in slave units [2FInp]
When enabled, this bit (bit1 must also be enabled) will cause the closing of the
"INPUT" to open the E-lock with the delay entered as the P12 program value.
When disabled, the bit will cause closing of the "INPUT" on the slave unit, with the
value set in the P12 program, to trigger a call to selected apartment.
Bit3.- Operation with optional electronic add-on module [3Hot]
Activation of this bit is necessary for the unit to communicate with electronic add-
on modules (or a computer via USB) connected to EXMOD sockets. By default
this bit is enabled.
Bit4.- Activation of further door opening pulse [4Cor]
This bit activates a function that is intended, after the door opening procedure at
the panel, to send a pulse that causes the further door opening function to be
activated in downstream units; Waiting for door opening at downstream units is
signalled by the "
“ symbol, shown on the display and the time till the function
is deactivated. When the "
key
" button is pressed now, it will cause immediate
activation of the E-lock, while pressing the "#" button will cancel this option. If bit1
is enabled, the E-lock may turn on automatically after the set time has elapsed
without pressing the button. The further door opening function activation time is
programmed in each unit in the P6 program (must be different from zero) and is
counted from the moment the opening procedure is finished in the upstream unit.
Bit5.- Dialling in hotel mode [5Hot]
When this bit is enabled, the unit is set to the Hotel system mode. Enabled bit
a
llows “entry” to the P10 program, where parameters of this mode can be
configured.
Bit6.- Changing the direction of the call number offset [6+-Mv]
This bit sets the direction of the call number offset:
-
“
Subtracting
”
:
bit disabled - "0" (by default). In this setting, the unit subtracts
the value of the offset set in P9 from the apartment number selected on the
keypad and makes a call to the uniphone with physical address resulting from
this difference.