background image

E

C320 User settings manual 

41 

J-JY-EC320 

 

 

 

2

  Data editing 

In practical applications, we sometimes need to edit the read data before outputting it, 
which is convenient for data differentiation and processing. 

Date editing as follows: 

 

Add Prefix 

 

Add Suffix 

 

Decoding information Data segment interception 

 

Output barcode type  

 

Decoding failed will output specific RF information character 

 

Add terminating character Tail 

The default output order of processed data is as follows: 

Prefix

】【

CodeID

】【

Data

】【

Suffix

】【

Tail

 

 

2.1

  Prefix 

Add Prefix 

The prefix is a string that is modified by user-defined before the information is decoded. It can be 
added by scanning the “Add prefix” setting code. 

 

Add Prefix 

Clean All Prefix 

 

Modify Prefix 

Scan the "Modify Prefix" setting code and combine the scan data setting code,the user can modify the 

prefix content. It uses two hexadecimal values for each prefix character. The prefix allows up to 15 

characters. The hexadecimal conversion table of character values reference Appendix D. 

   

Modify Prefix 

  

e.g.,modify the user-defined prefix to "DATA" 

Summary of Contents for EC320

Page 1: ...EC320 User settings manual I J JY EC320 The right product for your great idea EC320 User Settings Manual...

Page 2: ...EC320 User settings manual II J JY EC320...

Page 3: ...user can save the configuration that he often uses as the default setting of the user By scanning Save current settings as user default settings the current configuration information of the device ca...

Page 4: ...ration to ensure smooth communication and correct content Serial output The serial communication interface of the reading module uses a TTL level signal TTL 232 which adapts to most system architectur...

Page 5: ...EC320 User settings manual 5 1200bps 4800bps 9600bps 14400bps 19200bps...

Page 6: ...Quick Configuration In order to help customers quickly configure to serial port and full code open mode during the secondary development process you can scan the following configuration code to achiev...

Page 7: ...vice by scanning the following setup code 1ms 3ms 5ms 10ms You can also modify the interval between valid messages and released messages by scanning the following 0ms 1ms 5ms 10ms 15ms You can also mo...

Page 8: ...EC320 User settings manual 8 0ms 1ms 5ms 10ms 15ms...

Page 9: ...scanning the following setup code Off On 1 1USB virtual serial port When the reading module is connected to the host using a USB cable the reading module can be configured as a virtual serial port ou...

Page 10: ...anual mode In this mode after the reading module is idle for a certain period of time it automatically enters the deep sleep mode which can be set by the following setting code Enable hibernation Disa...

Page 11: ...the user can also click the trigger button to manually pause the reading Clicking the trigger button to read the module will continue to cycle through the code continuous mode Reading interval This p...

Page 12: ...rwise the output is not allowed Same barcode reading delay same barcode reading not delayed Same barcode reading delay time When the same barcode reading delay is enabled the same barcode reading dela...

Page 13: ...on Automatic mode Reading interval After reading the successful output information or the single reading timeout the reading module needs to be separated for a period of time settable before re enteri...

Page 14: ...EC320 User settings manual 14 1000ms 2000ms...

Page 15: ...a continuous period of time in this mode so that the same barcode setting code can be read the same as the continuous mode 3 4 Command Trigger Mode In this mode the reading module starts reading the...

Page 16: ...me that the reading module is allowed to continue to collect and recognize before the reading is successful The single reading time setting range is 0 1 25 5 seconds and the step size is 0 1 second Wh...

Page 17: ...anywhere on the screen Full area 1 1 only the central area When the reading area is the center area the center position of the barcode must be within the set center area and the barcodes that are not...

Page 18: ...EC320 User settings manual 18 Modify the size of the center area...

Page 19: ...canning the Modify Center Area Size setting code Modify the size of the center area Example Modify the center area size to 50 1 Check the character table to get the hexadecimal value of the 50 four ch...

Page 20: ...Steady light The illuminator continues to illuminate after the reading module is turned on No lighting The light does not illuminate under any circumstances ordinary Constantly bright No lighting 1 2...

Page 21: ...assive intermediate frequency Buzzer drive frequency passive high frequency Buzzer drive frequency active drive In the active buzzer mode the read buzzer working level high can be set to buzzer idle l...

Page 22: ...33 J JY EC320 Reading turn off the decoding success prompt tone can prohibit the bar code reading success from prompting the sound and read turn on the decoding success prompt tone to resume the bar c...

Page 23: ...ble the reading module to read Chinese barcodes of various encoding formats it can be set by reading the input data encoding format Input data encoding format GBK Input data encoding format UTF8 Input...

Page 24: ...EC320 User settings manual 35 J JY EC320 Output data encoding format GBK Output data encoding format UNICODE...

Page 25: ...ettings In order to enable the host of each country to use the device it can be set by reading the keyboard of the corresponding country Keyboard United States Keyboard Czech Republic Keyboard France...

Page 26: ...ual keyboard function After the virtual keyboard is enabled it can be output in any keyboard mode but it will lose relative output efficiency In addition when using a virtual keyboard you must ensure...

Page 27: ...n practice we will encounter images that are mirrored or flipped vertically as shown in the following image When the barcode is flipped the mirror flip mode can be entered by scanning the correspondin...

Page 28: ...th normal and reverse barcodes One dimensional bar code forbidden color decoding One dimensional barcode enabling reverse color decoding 2D barcode anti color decoding 2D barcode enabling reverse colo...

Page 29: ...EC320 User settings manual 40 J JY EC320 Read version information...

Page 30: ...tput order of processed data is as follows Prefix CodeID Data Suffix Tail 2 1 Prefix Add Prefix The prefix is a string that is modified by user defined before the information is decoded It can be adde...

Page 31: ...tting code Add Suffix Clean All Suffix Modify Suffix Scan the Modify Suffix setting code and combine the scan data setting code the user can modify the Suffix content It uses two hexadecimal values fo...

Page 32: ...Y EC320 2 3 CODE ID Add CODE ID Users can identify different barcode types by CODE ID The CODE ID corresponding to each barcode type can be modified freely and the CODE ID is identified by one charact...

Page 33: ...responding to each bar code is represented by a hexadecimal value For the hexadecimal conversion table of character values refer to Appendix D e g modify the CODE ID of the CODE 128 barcode to A 1 Che...

Page 34: ...EC320 User settings manual 40 J JY EC320 Modify CODE ID of UPCA Modify CODE ID of UPCE0 Modify CODE ID of UPCE1 Modify CODE ID of CODE 128...

Page 35: ...ODE 39 Modify CODE ID of CODE 93 Modify CODE ID of CODE BAR Modify CODE ID of Interleaved 2 of 5 Modify CODE ID of Industrial 25 Modify CODE ID of Matrix 2 of 5 Modify CODE ID of CODE 11 Modify CODE I...

Page 36: ...EC320 User settings manual 41 J JY EC320 Modify CODE ID of RSS Omnidirectional Modify CODE ID of QR CODE...

Page 37: ...module adds the corresponding terminator after decoding the data Disable terminator Add terminator CR Add terminator TAB Add terminator CRLF 2 5 Data segment interception This function can be turned o...

Page 38: ...EC320 User settings manual 42 J JY EC320 Transfer the entire Data segment Transfer only the Start segment...

Page 39: ...and the conversion table of the hexadecimal value corresponding to the length M can be referred to Appendix D Cut length M before modification Modify the length of the END segment N Scan the cut leng...

Page 40: ...03 2 Confirm that the setup code is enabled If it is not enabled please scan the Enable Setup Code setup code see section 1 5 2 3 Scan the Cut length N after modification setting code 4 Scan the data...

Page 41: ...setting code The user can modify the RF information content It uses two hexadecimal values for each RF character The RF can allow up to 15 characters The hexadecimal value of the character value conv...

Page 42: ...e serial virtual serial port mode by scanning the following setting code The format output with protocol is selected and the format is as follows 03 length decode data In addition when the protocol ou...

Page 43: ...s Disable read all types Open the default reading type 3 2 Bar code rotation function Reading the following setup code will allow 360 rotation reading for all supported barcode types Disabling 360 rot...

Page 44: ...EC320 User settings manual 55 J JY EC320 Enable angle enhancement Disable angle enhancement...

Page 45: ...ng setup code to configure EAN13 add on code read enable or disable Disable 2 digit add on code Enable 2 digit add on code Disable 5 digit add on code Enable 5 digit add on code 3 5 EAN8 Read the foll...

Page 46: ...le 5 digit add on code 3 6 UPCA Read the following setup code to set the UPCA barcode enable disable reading Enable UPCA Disabled UPCA Read the following setup code to configure UPCA add on code read...

Page 47: ...EC320 User settings manual 58 J JY EC320 3 7 UPCE0 Read the following setup code to set the UPCE0 barcode enable disable reading...

Page 48: ...ng setup code to set the UPCE1 barcode enable disable reading Enable UPCE1 Disable UPCE1 Read the following setup code to configure UPCE1 add on code read enable or disable Disable 2 digit add on code...

Page 49: ...EC320 User settings manual 60 J JY EC320 Read the following setup code to set the Code128 barcode enable disable reading...

Page 50: ...128 Disable Code128 Read the following setup code to set the minimum length of the Code128 barcode minimum length 0 for Code128 Minimum length 4 for Code128 Read the following setup code to set the ma...

Page 51: ...0 for Code39 Minimum length 4 for Code39 Read the following setup code to set the maximum length of the Code39 barcode 51 J JY EC320 Enable Code39 Disable Code39 Read the following setup code to set...

Page 52: ...93 barcode 51 J JY EC320 maximum length 32 for Code39 maximum length 255 for Code39 Read the following setup code to configure whether Code39 supports Code32 mode and FullAsc mode Disable Code32 mode...

Page 53: ...0 for Code93 Minimum length 4 for Code93 Read the following setup code to set the maximum length of the Code93 barcode 52 J JY EC320 Enable Code93 Disable Code93 Read the following setup code to set...

Page 54: ...Bar Disable CodeBar Read the following setup code to set the CodeBar barcode enable disable send Start stop operator Enable CodeBar Start stop operator Disable CodeBar Start stop operator Read the fol...

Page 55: ...EC320 User settings manual 53 J JY EC320 maximum length 32 for CodeBar maximum length 32 for CodeBar...

Page 56: ...of 5 barcode enable disable reading Enable Interleaved2of5 Disable Interleaved 2 of 5 Read the following setup code to set the minimum length of the Interleaved 2 of 5 barcode minimum length 0 for In...

Page 57: ...ble Industrial25 Disable Industrial 25 Read the following setup code to set the minimum length of the Industrial 25 barcode minimum length 0 for Industrial25 Minimum length 4 for Industrial 25 Read th...

Page 58: ...llowing setup code to set the minimum length of the Matrix 2 of 5 barcode minimum length 0 for Matrix 2 of 5 Minimum length 4 for Matrix 2 of 5 Read the following setup code to set the maximum length...

Page 59: ...EC320 User settings manual 57 J JY EC320 Matrix 2 of 5 verification format is Mod10 Matrix 2 of 5 verification format is None...

Page 60: ...ode to set the minimum length of the Code11 barcode minimum length 0 for Code11 Minimum length 4 for Code11 Read the following setup code to set the maximum length of the Code11 barcode maximum length...

Page 61: ...following setup code to set the minimum length of the MSI barcode minimum length 0 for MSI Minimum length 4 for MSI Read the following setup code to set the maximum length of the MSI barcode maximum l...

Page 62: ...l barcode enable disable reading Enable RSS Omnidirectional Disable RSS Omnidirectional Read the following setup code to set the minimum length of the RSS barcode minimum length 0 for RSS Minimum leng...

Page 63: ...EC320 User settings manual 61 J JY EC320 Enable DM Disable DM...

Page 64: ...module supports simultaneous decoding of multiple DM barcodes Disable simultaneous decoding of multiple DM barcodes Enable simultaneous decoding of multiple DM barcodes 3 21 PDF417 Read the following...

Page 65: ...e TTL 232 Baud rate 9600 check None Data bit 8 bit Stop bit 1 bit Hardware flow control No hardware flow control Mode parameter Default reading mode Manual mode Serial port trigger mode Single reading...

Page 66: ...ate 7E 00 07 01 00 2A 02 D8 0F After the host sends a serial command to query the baud rate the reading module will reply the following information returned messages Corresponding baud rate 02 00 00 0...

Page 67: ...0x92 UPC A c 0x93 UPC E0 c 0x94 UPC E1 c 0x95 Code 128 j 0x96 Code 39 b 0x97 Code 93 i 0x98 Codabar a 0x99 Interleaved 2 of 5 e 0x9A Industrial 2 of 5 D 0x9B Matrix 2 of 5 v 0x9C Code 11 H 0x9D MSI Pl...

Page 68: ...I Code table Hexadecimal Decimal character 00 0 NUL 01 1 SOH 02 2 STX 03 3 ETX 04 4 EOT 05 5 ENQ 06 6 ACK 07 7 BEL 08 8 BS 09 9 HT 0a 10 LF 0b 11 VT 0c 12 FF 0d 13 CR 0e 14 SO 0f 15 SI 10 16 DLE 11 17...

Page 69: ...EC320 User settings manual 63 19 25 EM 1a 26 SUB 1b 27 ESC 1c 28 FS 1d 29 GS...

Page 70: ...al 64 Hexadecimal Decimal character 1e 30 RS 1f 31 US 20 32 SP 21 33 22 34 23 35 24 36 25 37 26 38 27 39 28 40 29 41 2a 42 2b 43 2c 44 2d 45 2e 46 2f 47 30 48 0 31 49 1 32 50 2 33 51 3 34 52 4 35 53 5...

Page 71: ...EC320 User settings manual 65 39 57 9 3a 58 3b 59 3c 60 3d 61 3e 62 3f 63...

Page 72: ...imal Decimal character 40 64 41 65 A 42 66 B 43 67 C 44 68 D 45 69 E 46 70 F 47 71 G 48 72 H 49 73 I 4a 74 J 4b 75 K 4c 76 L 4d 77 M 4e 78 N 4f 79 O 50 80 P 51 81 Q 52 82 R 53 83 S 54 84 T 55 85 U 56...

Page 73: ...EC320 User settings manual 67 5b 91 5c 92 5d 93 5e 94 5f 95 _ 60 96 61 97 a...

Page 74: ...l character 62 98 b 63 99 c 64 100 d 65 101 e 66 102 f 67 103 g 68 104 h 69 105 i 6a 106 j 6b 107 k 6c 108 l 6d 109 m 6e 110 n 6f 111 o 70 112 p 71 113 q 72 114 r 73 115 s 74 116 t 75 117 u 76 118 v 7...

Page 75: ...EC320 User settings manual 69 7d 125 7e 126 7f 127 DEL...

Page 76: ...EC320 User settings manual 70 8 Appendix E Data code 0 9 0 1 2 3 4 5 6 7 8 9...

Page 77: ...EC320 User settings manual 71 A F A B...

Page 78: ...EC320 User settings manual 72 C D E F...

Page 79: ...ode is read and the data A B C and D are sequentially read if the Cancel the previous reading of one bit of data is read the last reading number D will be canceled if you read Cancel a series of data...

Reviews: