Chapter 4
76
Index of Symptom-to-FRU Error Message
LCD-Related Symptoms
Symptom / Error
Action in Sequence
LCD backlight doesn't work
LCD is too dark
LCD brightness cannot be adjusted
LCD contrast cannot be adjusted
Enter BIOS Utility to execute “Load Setup Defaults” on Exit screen,
then reboot system.
Reconnect the LCD connectors.
Keyboard (if contrast and brightness function key doesn't work).
LCD cable
LCD inverter
LCD
Main board
Unreadable LCD screen
Missing pels in characters
Abnormal screen
Wrong color displayed
Reconnect the LCD connector
LCD cable
LCD inverter
LCD
Main board
LCD has extra horizontal or vertical lines
displayed.
LCD inverter
LCD cable
LCD
Main board
Indicator-Related Symptoms
Symptom / Error
Action in Sequence
Indicator incorrectly remains off or on, but system
runs correctly
Reconnect the inverter board
Inverter board
Main board
Power-Related Symptoms
Symptom / Error
Action in Sequence
Power shuts down during operation
Power source (battery pack and power adapter). See “Power
System Check” on page 62.
Battery pack
Power adapter
Hard drive & battery connection board
Main board
The system doesn’t power-on.
Power source (battery pack and power adapter). See “Power
System Check” on page 62“.
Battery pack
Power adapter
Hard drive & battery connection board
Main board
The system doesn’t power-off.
Power source (battery pack and power adapter). See “Power
System Check” on page 62.
Hold and press the power switch for more than 4 seconds.
Main board
Battery can’t be charged
See “Check the Power Adapter” on page 63.
Battery pack
Main board
Summary of Contents for Aspire 9100 Series
Page 36: ...Chapter 1 29 ...
Page 46: ...39 Chapter 2 ...
Page 53: ...Chapter 3 46 ...
Page 58: ...51 Chapter 3 ...
Page 65: ...Chapter 3 58 ...
Page 66: ...59 Chapter 3 ...
Page 88: ...81 Chapter 4 ...
Page 92: ...85 Chapter 6 Aspire 9100 Exploded Diagram ...
Page 108: ...101 Appendix C ...
Page 111: ...Index 104 ...