![AccuTemp Accu-Steam G2 Series Service Manual Download Page 24](http://html1.mh-extra.com/html/accutemp/accu-steam-g2-series/accu-steam-g2-series_service-manual_456974024.webp)
Accu-Steam™ G2 Gas Service Manual
23
SP8042-1911
Flame Sensor
AT2E-4717-1
Igniter
AT2E-4716-1
1. Unplug from wall receptacle.
2. Lower front access panel by removing
the screws in the upper corners of the
panel.
3. Remove orange flame sense wire (Fig
7.3G).
4. Remove screws and flame sensor.
5. Reinstall in reverse order.
1. Unplug from wall receptacle.
2. Lower front access panel by removing
the screws in the upper corners of the
panel.
3. Remove igniter wire.
4. Remove two nuts and igniter (Fig
7.3H).
5. Reinstall in reverse order.
6. Set new igniter gap between 1/8”-
3/16’’.
Fig 7.3H
Fig 7.3G
Ignition Cable
AT2E-1804-4
1. Unplug from wall receptacle.
2. Lower front access panel by removing
the screws in the upper corners of the
panel.
3. Remove ignition cable from igniter
and ignition module.
4. Apply dielectric grease to both cable
connector and install new cable.
Fig 7.3I