Accu-Steam™ G2 Gas Service Manual
11
SP8042-1911
D
Error Code
E001 or E002
on display
• E001: Open Temp (RTD) sensor J3-1 & J3-2. Check terminals for poor
crimping.
• E002: Shorted Temp (RTD) sensor J3-1 & J3-2.
• If RTD checks good, reconnect RTD and cycle power. Is error code still
present - Replace Temperature Controller.
E
Over temp
indicator
• If griddle is not warming up or holding a set point temperature, cycle
power.
• Check that incoming supply voltage is within spec for the unit.
• If Over Temp light goes out, monitor griddle to see if it over temps
again.
• If temperature is greater than 50 degrees different than measurement
device, verify measurement device.
• If measurement device appears to be accurate, measure ohms on
Control RTD. If reading is in error - replace Control RTD (Fig 4.B).
• If RTD measures normally, but the control is continually calling for heat
- replace temperature controller.
• If Control RTD and control board are operating normally, check Hi Limit
RTD for proper values at current temperature.
• If temp/resistance values match RTD, replace Over Temp Thermostat.
• If values do not match RTD, replace Over Temp RTD.
SCHEMATIC,
G2 GRIDDLE
Fort Wayne, IN 46825
AT2T-3912
-1 Rev A
8415 N. Clinton Park
AccuTemp Products, Inc.
AT2T-3912-1
120V-240V
ACCU-STEAM G2 GAS
GRIDDLE
YEL
ORN
BRN
VIO
BRN
YEL
BLU
YEL
BLU
RED
ORN
YEL
100 O
PRTD
1000O
PRTD
N.O.
N.C.
COM
7
4
1
N.O.
N.C.
COM
8
5
2
3
6
RLY 2
DC COIL
BRN
WHT/GRAY
GRY
WHT/BRN
WHT/BRN
OVER
TEMP
VIO
L1 L2 N.C. N.O. COM *RTD*
RESET
HIGH LIMIT
CONTROLLER
YEL
BRN
ZR1
38V
ZR2
38V
PV
MV
GAS VALVE
1
2
3
4
5
6
SPARK
MODULE
GRN
HV IGNITOR
BURNER
BLK
WHT
GRN
2
1
WHT
BLK
RED
YEL
BLU
HEAT
RED
RED
BLK
WHT
240V
208V
120V
COM
24V
RED
ORN
.75 A
F2
.75 A
F1
IGN FAULT
BLU
WHT
FAULT
TIMER
1
2
3
1
2
J2
POWER
INPUT
DIGITAL
CONTROLLER
ON/
OFF
1
2
3
4
5
6
J7
+24V
GND
1 2
J3
SENSOR
INPUT
1
2
3
4 5
ISSP
YEL
VIO
GRN
1
2
J1
3
4
OPTIONAL
REMOTE
TIMER
AT0A-2779-5
TRANSFORMER ASSEMBLY
AT0E-3625-5
Control Board
AT0E-3880-1
HI-LIMIT CONTROL
AT0E-2825-6
Relay, DC
AT0E-1800-2
PILOT LAMP, RED
AT2E-1807-1
IGNITION CONTOL MODULE
AT2E-4717-1
FLAME SENSE PROBE
AT2E-4716-1
IGNITOR
AT2E-1806-2
NG CONTROL VALVE
AT2E-1806-3
PROPANE CONTROL VALVE
AT0E-2885-7
HI-LIMIT SENSOR
AT0E-2885-8
TEMPERATURE SENSOR
AT0A-2911-1
AC POWER CORD ASSEMBLY
AT0E-2500-3
TIME DELAY RELAY
AT2B-2099-2
36"& 48"
BURNER
AT2B-2131-2
24"
BURNER
Fig 4.B
AT0E-2885-3
HI-LIMIT SENSOR
Summary of Contents for Accu-Steam G2 Series
Page 34: ......