Accu-Steam™ G2 Gas Service Manual
15
SP8042-1911
Managers mode is used to setup initial operational parameters for the appliance prior to the first
time of production use.
Manager’s mode
1. Entering Managers mode, press and hold the
DOWN arrow key and the Asterisk key
together for about eight seconds, to initiate the programming mode. When the mode is
accessed, all three LED lights will blink synchronously.
2. Once in managers mode, the display will show the DEFAULT COOK TEMP, (see Fig 4.E,
P# 1
)
3. To cycle between programs, use
UP arrow key and
DOWN Arrow key. For example, to
reach Program #2, Ready Mode Display, the
UP arrow would be pushed once, cycling from
Program #1 Default Cook Temperature to Program #2.
4. To adjust the selected program, use
Preset 2
key or Asterisk key to adjust the Program Settings
(Fig 4.E & 4.F).
5. When all changes are completed Exit the Managers mode and save the new parameters by
pressing the
Preset 1
key
P#2
Value
Default
Display
Display when there is a
,
or momentary key press
Display when there is a
key press
0/00
rdY
Set Point Temperature
Set Point Temperature
1/00
Set Point Tempera-
ture
Set Point Temperature
Actual Temperature
2/00
rdY
rdY
rdY
3/00
Set Point
Set Point Temperature
Set Point Temperature
This chart illustrates the programming logic and program level indication
Programming Example - Adjusting the Default Temp.
1. Press and hold the
DOWN arrow key and the Asterisk key together for about eight
seconds, to initiate the programming mode. When the mode is accessed, all three LED lights
will blink synchronously.
2. The display will show the default temperature (350°F from factory).
3. Use the use
Preset 2
key or Asterisk key to increase or decrease the temperature on the
display.
4. With the desired temperature displayed the
Preset 1
key to save. The unit will power down.
5. When the unit is restarted, the display will now show the new default temperature and start
heating.
5.2 Managers Mode
Fig 5.B
Fig 5.C
Mode P#
LED1 LED2 LED3 Program description
Default
Display
Min Setting Max Setting
0
B
B
B
Unit of Measure
(°F)
0/00
0/00 = F
0/01 = C
1
B
B
B
Default Cook Tempera-
ture
350F
175C
350F
175C
200F
90C
400F
205C
2
B
B
B
Ready Mode Display
0
2/00
0
3
3
B
B
B
Probe Offset
-10
+10
0
0
Summary of Contents for Accu-Steam G2 Series