![AccuTemp Accu-Steam G2 Series Service Manual Download Page 23](http://html1.mh-extra.com/html/accutemp/accu-steam-g2-series/accu-steam-g2-series_service-manual_456974023.webp)
Accu-Steam™ G2 Gas Service Manual
22
SP8042-1911
Gas Valve
AT2E-1806-2
Ignition Control Module
AT2E-1807-1
1. Unplug from wall receptacle.
2. Lower front access panel by removing the
screws in the upper corners of the panel.
3. Locate the module and remove wires (Fig
7.3F).
4. Remove hardware securing module.
5. Remove module.
6. Reinstall in reverse order.
7. Dielectric grease AT0E-3540-3 should be
applied to all pin connections.
1. Unplug from wall receptacle.
2. Turn off gas supply and disconnect the unit
from supply hose.
3. Lower front access panel by removing the
screws in the upper corners of the panel.
4. Take note of or mark wire location and
remove wires.
5. Disconnect brass gas lines from cross
fitting.
6. Disconnect union and remove assembly.
7. Remove cross fitting.
8. Reinstall in reverse order; applying new
pipe dope to fittings.
Solenoid terminals - use circled
terminals only for wire connections
Fig 7.3F
Fig 7.3D
Fig 7.3E
Ensure there is no damage to the rubber
boot on the ignition cable were it connects to
the ignition module.