Manual Part # 800-1402-002 Rev K, 072418
Page 39 of 53
S
ECTION
4
R
EADOUT
P
ROGRAMMING
Many functions of these Digital Readouts are user programmable and may
need to be configured for different applications.
Key Timing
Several keys on the Readouts have multiple functions. The function that is
executed when a key is depressed is dependent on how long the key is
depressed. Therefore, how long the key is depressed is important.
This manual uses the term “
Momentarily
” to describe a key depression of less
than .8 seconds, and
“Press and Hold
” to describe a key depression of longer
than 1 second.
For Momentary key operations, the Key Function is executed on release.
For Press & Hold operations, the Key Function is executed after the key has
been depressed for the prescribed amount of time.
Resetting All Parameters
To reset all programming parameters to their Factory Default settings:
1.
Turn the Readout power off.
2.
Insure
3.
Press and Hold
the
ON
/
OFF
and
UNITS
keys for 10 seconds.
The Readout will:
1.
Perform a full segment LCD test
2.
Display the current firmware version
3.
Reset all programming parameters to factory default values.
(not recommended unless instructed by factory technician)
of this manual for settings particular to this readout.
for a list of Factory Defaults.
Momentarily
Press & Hold
How long a key is pressed?
Less than .8 seconds
More than 1 second
When is the key function executed?
On key release
While holding
Press & Hold