Manual Part # 800-1402-002 Rev K, 072418
Page 37 of 53
Circuit Board Jumpers
JP1
FACTORY USE ONLY
JP2
FACTORY USE ONLY
Position A ONLY
JP3
Programming Lock-out
Default = Position A
Front panel programming of the Readout can be enabled or disabled though
the use of this circuit board jumper.
Front panel Programming is enabled when the shorting jumper is installed in
position
A
. To disable Front panel Programming, install jumper on position B.
When programming is disabled, user cannot access the programming functions
via the
front panel as described in the
This
provides a method of configuring the Digital Readout with specific parameters,
and preventing unauthorized or accidental changes.
JP4
Readout Power Selection
Default = Position B
The General Purpose and In-Panel Readouts operate on either on internal
battery power or external 12-24VDC. When this jumper is installed in the
B
position, the Readout is powered from the internal battery. When this jumper is
installed in position A, the Readout must be powered by 12-24VDC DC.
JP5
Input/Output Selection
Default = Position A
The General Purpose and the In-Panel Readouts have connections used for
External Power or an Input/Output connection. This jumper is used to configure
the connections as Inputs or Outputs. In position
A
, the connections are
configured for OUTPUT. In the B position, the connections are configured as
INPUTS
See: