Operation Manual for LCD Digital Readouts
Page 14 of 53
12-24VDC
Common
Common
12-24VDC
Input/Output
Input/Output
12-24VDC Operation
The General Purpose and the In-Panel Readouts will operate on 12-24VDC.
The General Purpose Readout uses a multi-purpose plug-in connector for
power as well as
The In-Panel Readout uses screw terminals for these connections.
Also,
See Section 3: Circuit Board Jumpers
General Purpose Readout
In-Panel Readout
When powering Readouts with 12-24VDC, the Scale and the Readout common
must be connected to each other, or connected to each other via a common
point. A proper connection will eliminate ground loops that may cause unstable
readings on the Readout.
NOTES: When using Model 150, 250 or 950 operated on 12-24VDC, use
only Scales, & Encoders with
part #’s end in ‘G’.
12-24VDC Readouts are designed to run on DC VOLTAGE ONLY.