Parts Identification, Removal and Installation
Gas Valve
AT2E-1806-2
Ignition Control Module
AT2E-1807-1
1. Unplug from wall receptacle.
2. Lower front access panel by removing the screws in
the upper corners of the panel.
3. Locate the module and remove wires.
4. Remove hardware securing module.
5. Remove module.
6. Reinstall in reverse order.
1. Unplug from wall receptacle.
2. Turn off gas supply and disconnect the unit from
supply hose.
3. Lower front access panel by removing the
screws in the upper corners of the panel.
4. Take note of or mark wire location and remove
wires.
5.
Disconnect brass gas lines from cross fitting
6. Disconnect union and remove assembly
7.
Remove cross fitting
8. Reinstall in revers order; applying new pipe
dope to fittings