11 - SECTION F
WIRING DIAGRAMS
HUB RADIATOR PLUS 250 - 400 SOLAR
11.1 KEY OF ELECTRICAL DIAGRAMS HUB RADIATOR PLUS 250 - 400 SOLAR
All the products of the HUB RADIATOR PLUS SOLAR
series they are equipped with a 2000W single-phase electrical
resistance.
This resistor can be used either as a replacement
of the heat pump that integrates it.
the type of operation can be selected using the buttons
on the control plate of the cabinet of external cover.
A) OPERATION ONLY HEAT PUMP
The “IR” button in the figure must be in the OFF position
“key O”, in this way the resistance electric will never go
into operation
B) OPERATION WITH ACTIVATED SUPPORT RESISTANCE
To use the integration resistance just press the “IR” key
in the ON position “I key” and the “DR” INTEGRATION
“key II” key. In this way the control unit will decide when
it is necessary the help of the resistance that will work
in tandem to the heat pump.
C) OPERATION WITH ALWAYS ACTIVE RESISTANCE
To use only the resistance in place of the pump
heat, just press the “IR” button
in the ON position “I key”
and the “DR” EMERGENCY “key I”.
IR
resistance switch
O
I
OFF
ON
IPI
system pump switch
O
I
OFF
ON
DR
resistance diverter
EMERGENZA
I
I I
INTEGRAZIONE
ICS
solar control unit switch
O
I
OFF
ON
LEGEND
M1
terminal block Booster 1
M2
terminal block Booster 2
Pb1
technical water probe
Pb3
battery probe Booster
Stc
compressor thermal probe
Tr
transformator 230V - 12V
R1
electrical resistance relay
RD
diverter relay
RP
system pump relay
RT
voltage mounting relay (3)
RR
electrical resistance relay
RB
Booster 3.0 compressor relay
TA
room thermostat
R
electrical resistance 2000W (4)
CD
digital controller DIXELL
VD
diverter valve (2)
P pump
Cr
remote control (1)
TM
minimum thermostat
MT
differential magnetothermic (5)
IR
electrical resistance switch
DR
electrical resistance diverter
ICS
solar control unit switch
IPI
system pump switch
VD (2)
RT (3)
Letter
A
diverter
valve flow fed to
the system
Letter
B
diverter valve not
powered DHW
priority
Letters
AB
circulator side
Relay setting
Voltage monitoring
Umax 253 V
Umin %80
T 8 s
OK
U<Umin
U>Umax
N.B. Before making connections
make sure you have
correctly sized the section
of the power cables
based on the actual distance
from the counter.
Always foresee a special
protection magnetothermic
(5)
differential magnetothermic MT
N.B. Not supplied as standard,
to be calculated by an electrical designer.
Cr (1)
Remote Command
P 15
R (4)
Resistance Relay
Electric