27
which certifies that the work has been carried out in a workmanlike
manner, in accordance with the rules and regulations in force.
Incorrect installation can cause damage to people, animals and
things, for which the manufacturer cannot be held responsible in
any way.
Therefore, to install the panels it is necessary to follow the
instructions provided by the manufacturer in the instruction
booklet supplied with the appliance.
DANGER!
NEVER try to carry out maintenance work or repairs on the
system on your own initiative.
Any intervention must be carried out by professionally qualified
personnel, it is advisable to stipulate a maintenance contract.
Poor or irregular maintenance can compromise the operational
safety of the system and cause damage to people, animals and
things for which the manufacturer cannot be held responsible.
CHANGES TO PARTS CONNECTED TO THE EQUIPMENT
Do not make changes to the following elements:
- to the water and electricity supply lines
- construction elements that affect safety operating device
The use of untested or unsuitable connection and safety devices
or materials for use in solar systems (eg expansion vessels,
pipes, insulation) is prohibited
It is forbidden to disperse or leave packaging material within the
reach of children as it is a potential source of danger.
Do not leave tanks of antifreeze liquid unattended as, if
accidentally ingested, it can be toxic.
Use the antifreeze liquid only and exclusively as a heat carrier
inside the solar collectors, diluted according to the design
instructions.
Some parts of the solar collector can reach high temperatures
and cause burns, make sure they cannot accidentally come
into contact with people, animals and objects sensitive to high
temperatures.
For the assembly of the solar collectors, before starting the work,
the safety regulations in the workplace must be strictly observed
and all the protective structures provided for by them such as
fall protection, safety nets for scaffolding, must be implemented.
coveralls with tie-down or restraint belts, etc.
The equipment used must also comply with current legislation.
During work it is mandatory to wear protective goggles, safety
shoes, cut-resistant work gloves and a helmet.
After removing the packaging, ensure the integrity and
completeness of the supply and in case of non-compliance,
contact the supplier company that sold the collectors.
TECHNICAL DATA PLATE
The technical data plate is placed on the side wall of the
appliance.
Tampering, removal, lack of identification plates or anything else
that does not allow the safe identification of the product, makes
any installation and maintenance operation difficult.
“MOTHER COMPANY”
NAME Made in
____________________
MATR
Anno
____________
solar collector
“MODELLO”
DIMENSIONS OF THE COLLECTOR
xxx mt
GROSS COLLECTOR SURFACE
xxx mq
EMPTY WEIGHT
xxx kg
VOLUME OF THE EAT TRANSFER FLUID
xxx lt
STAGNESS TEMPERATURE (1000 W/mq 30 °C)
xxx °C
MAXIMUN WORKING PRESSURE
xxx bar
PROTECTIVE FILM
The manifolds relating to the SELECTIVE H + and SELECTIVE
HX + series are supplied with a protective film adhering to the
glass.
This film has the function of protecting the most sensitive
components of the collector (eg: glass gasket, pipe guide, ...) if it
is installed on the roof, without starting the system with theì
relative load of antifreeze liquid solution.
This situation can represent a rather critical condition because
the heat absorbed by the collector has no possibility of
being transferred through the heat transfer fluid to the water
accumulation, located in the technical room or nearby.
The film therefore has the function of temporary protection of the
collector and must be removed as soon as the system comes
into operation.
The film has been tested for a duration of 1 month; therefore it is
recommended to remove it within this period.
A longer period of permanence can cause the film to lose its
adhesive characteristics or deteriorate, making it difficult to
remove.
Removal takes place with a simple tearing gesture, starting from
one corner.
The film is made of low density polyethylene, with the visible
surface in white color; the adhesive part is made of rubber.
Below is the adhesive label that is applied to the film, in order to
clearly inform the installer about the above information.
PROTECTIVE COVER TO BE
REMOVED WITHIN MAXIMUM 1
MONTH OF INSTALLATION
AS PER SPECIFICATIONS IN THE MANUAL
LIGHTNING AND OVER VOLTAGE PROTECTION
If there is a lightning protection system in the building, the
collector system must be connected to this system.
For integration, an electrical connection must be established via
copper cable (minimum section 10 mm2) between the mounting
frames and the piping.
The pipes must be electrically connected to the main equipotential
connection by means of a cable with a minimum section of 10
mm
2
.
Observe local lightning protection regulations.
A lightning equipotential bonding must be made in each system
according to the ENV 61024-1 standard and the VDE 0185
standard.