LED Display
Definition
Parameter
Table
Description
Note(F1-3 over-current setting in Hall sensor mode):
Only in “F1-3”Hall sensor mode, the PCB will record all the current value in learning mode. Please adjust over current value
by setting F3 function after learning mode.
The recorded current values will increase according to the value shown on LED display as over current value.
FJ
Over Current Reverses
Time when Close
FJ-0
FJ-1
FJ-2
FJ-3
FJ-4
FJ-5
FJ-6
Function OFF
0.1 sec
0.2 sec
0.3 sec
0.4 sec
0.5 sec
0.6 sec
1. The factory setting is "FJ-0"
The value can be adjusted by pressing button UP and DOWN. The maximum value is 50(5.0A) and the minimum value is 05(0.5A).
LED display example:
Indicate 1.0 ampere: all of the
recorded values will increase 1
ampere as over current value.
Indicate 2.8 ampere: all of the
recorded values will increase 2.8
ampere as over current value.
Indicate 0.6 ampere: all of the
recorded values will increase 0.6
ampere as over current value.
1
22
Opening your life