Safety For Gate Operation
6) LED Indication
Gate Operation Logic
A) In gate-opening phase: The gates stop if the transmitter/push button/key selector is activated, and close when
the transmitter/push button/key selector is reactivated.
B) In gate-closing phase: The gates stop if the transmitter/push button/key selector is activated, and open when
the transmitter/push button/key selector is reactivated.
LED Lighting
LED2 RF : Key selector, or the push button is activated, LED2 will be on.
LED4 Ph1 : LED4 will be on when Ph1 are triggered.
LED3 Ph2 : LED3 will be on when Ph2 are triggered.
In gate-opening phase: For safety purpose, the gates stop if encountering obstacles.
In gate-closing phase: For safety purpose, the gates reverse for 2 sec if encountering obstacles.