Photocell OPEN/CLOSE (Standard set up)
When safety devices are activated
Safety Edge
Open Only Device (Vehicle detector)
Type of Safety Device
FULLY CLOSED
FULLY OPENED
STOP DURING MOVING
CLOSING
OPENING
PH1
Photocell-CLOSE
No effect
Reload automatic closing time
Open
No effect
PH2
Safety Edge
Open not allowed
OPEN/CLOSE not allowed
Reverse to open for 2 seconds
Reverse to close for 2 seconds
Photocell Logic
Position of Gate
When safety devices are activated
Position of Gate
Type of Safety Device
FULLY CLOSED
FULLY OPENED
STOP DURING MOVING
CLOSING
OPENING
PH1
Photocell-CLOSE
No effect
Reload automatic closing time
Reload automatic closing time
Open
No effect
PH2
Photocell-OPEN
Open not allowed
No effect
Open not allowed
No effect
Close
Reload automatic closing time
Type of Safety Device
FULLY CLOSED
FULLY OPENED
STOP DURING MOVING
CLOSING
OPENING
PH1
Photocell-CLOSE
No effect
Reload automatic closing time
Open
No effect
PH2
Opening Device
Open
Open
Open
No effect
When safety devices are activated
Position of Gate
Reload automatic closing time
1
23
Opening your life