Function of the LED display
LED Display Programmable Functions
Pantalla LED Funciones Programables
When the gate is opening, the LED Display
show ‘OPN’ for 2s and then change to Amp
current indication
All memories of the system are deleted/-
cleaned by press and hold the UP + SET+
DOWN button together for 5s, and then, the
panel will back to default settings.
When the gate is stopped, the LED Display
show ‘STP’ until next commend has been made,
after 10s no further movement, the LED turns to
OFF
When the gate is closing, the LED Display show
‘CLS’ for 2s and then change to Amp current
indication
LED display show “S03” means same button on
the remote has been identified for more than 2
functions
LED display shows “S02” means the panel did
not detected the M1+/M1 but detected M2+/M2
been connected, notice the installer to check the
motor wire connection, if this is single gate
system, motor wire should connect to M1+/M1
not on M2+/M2
LED display shows “S01” means the panel did
not detected the M1+/M1 and M2+/M2 both
been connected before the system learning
procedure, check for 2 motors’ wire connection,
for dual gate system
Antenna
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16 17 18
19 20 21 22 23 24 25 26
Lit+ Lit- Lat+ Lat- M1+ M1- M2+ M2-
5V S1 S2 GND Lmt1 Lmt2 GND Lmt3 Lmt4 GND
GND
Ph1
Ph2
PhVcc
PhVcc
GND
DKey SKey
LED 2 LED 4 LED 3
[LEA] means motor into the system learning
mode, do not interrupt during this procedure.
[D-G] means motor completed the learning
procedure for dual gate installation.
[S-G] means motor completed the learning
procedure for single gate installation.
[N-L] means system learning failed.
1
17
Opening your life
AC24NE