ADSP 8
42
42
C. Release time: it means when the level of the output signal is varied by the level
of over limiter less than the level of the limiter, how long the limiter takes to shrink.
Normally it is the best to adjust the time release longer than the response time
adjusting range: 50mS~50000mS.
Setting advise: better bass signal release time is better in the range:
600mS~800mS, mid-high signal release time in the range 200mS~400mS.
Click “cancel” to exit.
(2) Firmware Upgrade
Click “firmware updates” and the pop-up dialog appears as below, click
“browse the file dialog” button and find *hex Extension DCP680 upgrade files and
click “update” button to upgrade the hardware. The upgrade progress begins with
color that start to move, after around 60 seconds the progress bar is full that
means the hardware upgrade was successful. Click the “exit” button to exit the
hardware update. After the updates, the machine will restart automatically.
Note:
the upgrade files*. Extension DCP680 can be downloaded from our
website, which is the latest version of the software update.
Please don’t turn the power off during the update!!!
(3) Help Menu:
Left-click the “help” and the machine’s help files pop-up including:
operation instruction, the installation dimension, etc.
(4) About:
Display the version of the software, copyright info, etc.