background image

 

Preface 

Dear customers, many thanks for your purchase of this wireless external siren. In choosing our product, you now have 
a piece of equipment that is built according to state-of-the-art technology. 

This  product  complies  with  current  domestic  and  European  regulations.  Conformity  has  been  proven,  and  all  related 
certifications are available from the manufacturer on request. 

To maintain this status and to guarantee safe operation, it is your obligation to observe these operating instructions! In 
the event of questions, please contact your local specialist dealer. 

 

 

 

 

Pay  attention  to  the  notes  and  instructions  in  these  operating  instructions!  If  you  do  not  follow  these 
instructions, your guarantee claim becomes invalid! No liability can be accepted for resulting damages! 

No part of the product may be changed or modified in any way.  

Please  take  local  regulations  into  consideration.  In  some  European  countries,  the  use  of  external  sirens  is 
forbidden or the maximum alarm duration is restricted. Contact your local authorities for more information. 

When  inserting  the  battery  into  the  siren,  a  loud  tone  may  be  emitted  by  the  signal  transmitter.  This  may 
startle the operator. Ensure that you do not lose your balance or drop the siren. 

Introduction 

The FUSG50000 wireless external siren is an optional accessory for the Secvest 2WAY, Secvest-IP or Terxon 2WAY 
module. It is battery-driven and is used for visual and acoustic alarms. 

 

Battery warning! 

The  device  is  supplied  with  direct  current  from  a  battery  back.  To  guarantee  a  long  working  life  and  avoid  fire  and 
injury, please note the following: 

 

Do not dispose of the battery in domestic waste. 

 

The battery must not be directly exposed to heat or sunlight, and must not be stored in a place with a very high 
temperature. 

 

The battery must not be burned.  

 

The battery must not come into contact with water. 

 

The battery must not be dismantled, pierced or otherwise damaged. 

 

The battery contacts must not be short-circuited. 

 

The battery must be kept away from small children. 

 

The battery cannot be recharged.  

 

 

Technical data 

Sound pressure 

105 dB (A) @ 1 m 

Visual alarm 

Flashing LED bar (can be positioned at top or bottom) 

Flash frequency 

1 Hz 

Sounds 

Alarm, Fire, Perimeter Warning, Conf-Beep 

Radio frequency  

868.6625 MHz 

Range 

Up to 100 m (depending on the surrounding conditions) 

Power supply 

2 X 3 V alkaline battery pack or 1 X 7.2 V lithium battery pack* (*recommended if the siren is 
regularly exposed to sub-zero temperatures) 

Battery service life 

Approx. 2 years 

Dimensions  

300 mm x 210 mm x 60 mm (HxWxD) 

Weight  

1200 g (without batteries) 

Security level 

Environment class 

IV 

Operating temperature 

-25 °C to +60 °C 

Ingress Protection Rating  IP42 

Housing material 

Polycarbonate (weatherproof) 

Summary of Contents for FUSG50000

Page 1: ...6 Sir ne radio ext rieure 2WAY Instructions d installation 10 Radiosirena esterna 2WAY Istruzioni per l installazione 15 Draadloze buitensirene 2WAY Installatie instructies 19 Tr dl s udend rs sirene...

Page 2: ...ist optionales Zubeh r f r die Funkalarmzentralen Secvest 2WAY Secvest IP oder das Terxon 2WAY Modul Sie ist batteriebetrieben und dient zur optischen und akustischen Alarmierung Batteriewarnhinweise...

Page 3: ...nahe von Wasser oder Gasleitungen innerhalb metallischer Geh use neben Elektronikger ten insbesondere Computer Fotokopierer und Radios ffnen des Geh uses und Einlegen der Batterien 1 Entfernen Sie di...

Page 4: ...rung bei Sabotage aber Meldung an die Alarmzentrale Je nach Einstellung gibt diese dann den Befehl zur Aktivierung an die Sirene oder nicht Sirenenabschaltdauer Die akustische Sirene schaltet sich nac...

Page 5: ...ng der Funkalarmzentralen Secvest 2WAY Secvest IP oder des Terxon 2WAY Moduls Wartung Blitz und Sirene sollten in periodischen Abst nden auf korrekte Funktionsweise berpr ft werden Dabei sollten Sie a...

Page 6: ...0 wireless external siren is an optional accessory for the Secvest 2WAY Secvest IP or Terxon 2WAY module It is battery driven and is used for visual and acoustic alarms Battery warning The device is s...

Page 7: ...rs and radios Opening the housing and inserting the batteries 1 Remove the covers on the two housing screws Loosen the screws until the siren can be opened 2 Hinge the cover to the side and remove it...

Page 8: ...t Siren unset period The acoustic siren switches off after the defined unset period or when a unset command is received from the control unit The unset period changes according to the jumper position...

Page 9: ...Y Secvest IP or Terxon 2WAY Module installation manual for more details Maintenance The flashing bar and siren should be checked on a regular basis Both tamper contacts should be checked during mainte...

Page 10: ...a sir ne ext rieure radio FUSG50000 est un accessoire optionnel destin la centrale d alarme sans fil Secvest 2WAY Secvest IP Terxon 2WAY Module Elle fonctionne par des batteries et sert la signalisati...

Page 11: ...r frig rateurs proximit de lignes principales d alimentation lectrique de conduites d eau ou de gaz dans des bo tiers m talliques pr s d quipements lectroniques et notamment d ordinateurs de photocopi...

Page 12: ...SAB OFF Pas d auto set en cas de sabotage mais message la centrale d alarme Suivant le r glage cette derni re donne l ordre de s activer ou pas la sir ne Dur e de marche de la sir ne La sir ne s tein...

Page 13: ...orrespondant des instructions d installation de la centrale d alarme Secvest 2WAY Secvest IP Terxon 2WAY Module Maintenance Le bon fonctionnement du flash et la sir ne doit tre contr l des intervalles...

Page 14: ...troduzione La radiosirena esterna FUSG50000 un accessorio opzionale per la centrale di allarme radio Secvest Funziona a batteria e serve ad emettere un allarmo visivo e acustico Avvertenza batteria Il...

Page 15: ...fotocopiatrici e radio Apertura del guscio e inserimento delle batterie 1 Rimuovere i coperchi delle viti che bloccano il guscio Svitare le viti tanto da consentire l apertura della sirena 2 Togliere...

Page 16: ...o prima di disattivare la sirena La sirena acustica si spegne trascorso il tempo di spegnimento impostato oppure quando riceve il comando di disattivazione dalla centrale di allarme L intervallo di te...

Page 17: ...tivo delle istruzioni di installazione della Secvest 2WAY Secvest IP Terxon 2WAY Module Manutenzione Verificare a intervalli di tempo regolari il corretto funzionamento del lampeggiatore e della siren...

Page 18: ...ntrale Secvest 2WAY Secvest IP Terxon 2WAY Module Ze werkt op batterijen en dient voor optische en akoestische alarmsignalen Waarschuwingen i v m de batterij Het toestel wordt door een batterijpack va...

Page 19: ...jder de afdekkingen van de twee vasthoudschroeven van de behuizing Draai de schroeven er zo ver uit dat de sirene kan worden geopend 2 Neem de frontafdekking van de sirene af en leg deze opzij 3 Schui...

Page 20: ...t commando ter activering aan de sirene of niet Sirene uitschakelduur De akoestische sirene schakelt uit na de vooringestelde uitschakelduur of zodra ze het commando ter uitschakeling van de alarmcent...

Page 21: ...van de Secvest 2WAY Secvest IP or Terxon 2WAY Module Onderhoud Flits en sirene moeten geregeld op hun goede werking worden getest Daarbij moet u de beide sabotagecontacten controleren Ga na of er wat...

Page 22: ...r option til den tr dl se alarmcentral Secvest 2WAY Secvest IP or Terxon 2WAY Module Den er batteridrevet og er beregnet til optisk og akustisk alarmering Batteriadvarselshenvisninger Apparatet forsy...

Page 23: ...e kopimaskiner og radioer bning af kabinettet og is tning af batterierne 1 Fjern afd kningerne fra de to kabinetholderskruer Skru skruerne s langt ud at sirenen kan bnes 2 L ft sirenens frontafd kning...

Page 24: ...andoen til aktivering til sirenen eller ikke Sirenefrakoblingstid Den akustiske sirene afbrydes efter den forindstillede frakoblingstid eller s snart den modtager kommandoen til frakobling fra alarmce...

Page 25: ...gen til Secvest 2WAY Secvest IP or Terxon 2WAY Module Vedligeholdelse Det skal kontrolleres med regelm ssige mellemrum at blitzen og sirenen fungerer korrekt I den forbindelse skal du ogs kontrollere...

Page 26: ...u Terxon 2WAY Jest ona zasilana z baterii i s u y do alarmowania optycznego i akustycznego Ostrze enia dotycz ce baterii Urz dzenie jest zasilane napi ciem sta ym z pakietu baterii Aby zapewni d ug y...

Page 27: ...alowych zbiornik w wody pojazd w i ch odziarek w pobli u przewod w energetycznych przewod w wodoci gowych i gazowych wewn trz obudowy metalowej w pobli u urz dze elektronicznych zw aszcza komputer w f...

Page 28: ...z centrali alarmowej ustawienie fabryczne Zworka zdj ta SAB wy brak autoaktywacji w razie sabota u ale jest wysy ana informacja do centrali alarmowej Zale nie od ustawienia centrala przesy a do syreny...

Page 29: ...na ten temat odpowiedni rozdzia w instrukcji instalacji radiowych central alarmowych Secvest 2WAY Secvest IP lub modu u Terxon 2WAY Konserwacja Nale y regularnie sprawdza prawid owo dzia ania lampy b...