35
Diagnosis > System
The event log can be read out using the 'System' sub-tab of the 'Diagnosis'
tab. The event log is divided into: transmission and system.
Done Green, AZWG10200-PSTN/IP CONVERTER is ready for operation
Red, AZWG10200-PSTN/IP CONVERTER is not (yet) ready (restart)
Log book
Green, log book available
Red, log book not available (not supported)
Error in index
An error has occurred in the listed index number, such as a
transmission error
Index
Consecutive number
Line
Input or output of the AZWG10200-PSTN/IP
CONVERTER
Notification
VdS, SIA or Contact ID notification
Trigger time
Time of alarm or fault
Acknowledged
Time of acknowledgement from receiver and
display of target
Clicking on the index line displays detailed data for the content of the
notification, including the processing time.
If there is an error in the index, clicking on the index for the content of a
notification displays detailed data for the error, including the processing time.