Time server
The AZWG10200-PSTN/IP CONVERTER uses the NTP time
server to synchronise the time automatically. With the
VdS 2465 and DC-09 protocols, the time is transmitted for each
notification for EN 50136 'Verification of Performance' (VoP). In
the case of public internet connections, the public addresses of
the time server should be entered here (e.g. ntp.pool.org or
NTP Deutsche Telekom AG: 195.145.119.188). If the
AZWG10200-PSTN/IP CONVERTER is used in a closed network
(VPN), the addresses of the VPN time server must be entered. If
no time server is available, the device does not transmit the
time with notifications. The AZWG10200-PSTN/IP CONVERTER
synchronises the time every hour via Ethernet or GSM.
Converter module
The converter module reads the Telim, SIA and Contact ID notifications from
the alarm system.
ON
Converter enabled
ON alarm system transmission
Selection for Telim, SIA or Contact ID alarm systems. The
level is automatically evaluated for SIA. Program 901 as the
first call number in the alarm system in order to enable
transmission through the AZWG10200-PSTN/IP CONVERTER.
'Transmission' tab
The communication options, the data of the IP receiver at the monitoring
station and the notification order are set in the 'Transmission' tab. The
AZWG10200-PSTN/IP CONVERTER provides a free choice between using the
primary path or opting for redundant transmission. Up to eight different
combinations of communication and receiver options can be set.
The settings consist of:
Module, communication via AZWG10200-PSTN/IP CONVERTER: