o
VdS Test report: selection for needs-based test
notification with VdS 2465 protocol.
o
Automatic test: standard SIA RP automatic test
notification.
o
Manual test: SIA RX test notification with the option
of transmitting the SIM ICCID number of the SIM
card in the text field of each test notification; %$01
must be entered in the text field for this purpose.
o
No reporting: no transmission.
o
Poll: setting for poll test notifications. Select 'Manual'
(specific timer setting) for EN risk class.
o
Timed function: setting for interval when measuring
analogue values such as temperature. The desired
interval must be set in the 'Advanced timer settings'
menu.
Function: for 'Timed function' only; select the line that
needs to transmit a current measured value after the
interval.
Text: free text field with max. 16 characters. This text is
sent with each test or poll notification. Only use if required,
because this option leads to excessive data amounts.
Advanced timer settings
The desired interval must be set here if a timer is enabled. An interval
can be set to daily, weekly or monthly via four tabs. Press 'Use per
timer' to apply the setting. [The current AZWG10200-PSTN/IP
CONVERTER, system, date/time and the next test notification are
displayed on the right-hand side.]
AZWG10200-PSTN/IP CONVERTER system
The system and transmission notifications can be set in this tab. The cover
switch is not used for the AZWG10200-PSTN/IP CONVERTER PCB.
Line:
Cover switch: not used
GSM IP; the locally monitored GSM/GPRS network
consists of: