The loading pixel dots of each network port cannot exceed 650,000 pixels. Before wiring, it is must be
connected according to the network cable load scheme designed before sales. The KL II series network
cables are loaded as below:
5.3 Power cord and signal test
After completing the cabinet wiring, please use a multimeter to measure whether there is a short circuit
at the AC input terminal (L/N/PE) and DC output terminal (VCC/GND) of the power supply. If you find a
short circuit, please check the wiring carefully. After ensuring that the line is normal, power on the
cabinet to work.
After confirming that the screen is energized normally, connect the computer and the sending box, and
use the NovaLCT software to configure the LED display screen configuration settings.
Note: For software operations, please refer to the Nova LCT software
operating instructions.
Product type
Cabinet size
Cabinet
resolution
Loading capacity for
each sending card
port
Remark
KL1.2 Ⅱ
640x360x65
512x288
≦4pcs cabinets
When calculating the
actual maximum
number of cabinets
loaded by a sending
card network port ,
calculate the number
of cabinets in the
rectangular area
loaded by the
network cable
KL1.5 Ⅱ
640x360x65
416x234
≦6pcs cabinets
KL1.8 Ⅱ
640x360x65
344x192
≦9pcs cabinets
KL2.5 Ⅱ
640x360x65
256x144
≦17pcs cabinets