Page 47
18.
SPECIFICATIONS AND RATINGS
These specifications are intended as a guide to proper use of the instrument. Specifications and
features will vary with application. AZI product specifications are controlled by ISO-9001
procedures and are established and verified during design. They are not to be construed as test
criteria for every application. Refer to AZI document Number 720-0036 for current
specifications controlling this instrument. All specifications and features are subject to change
without notice. Periodically contact Customer Service to see if any upgrades are available for
your instrument. Customer Service may be reached by phone at (800) 528-7411 or (602) 470-
1414. If you prefer the Internet, contact Customer Service at the Arizona Instrument web site,
http://www.azic.com
or e-mail direct at
.
Dimensions:
Approximately 150 mm (5.75”) H x 370 mm (14.5”) W x 360mm (14”) D
(not including the bottle loader/ramp).
Standard bottle loader/ramp adds about 90 mm (3.5”) to the width.
Weight:
Approximately 8.6 kg (19 lbs.)
Sample Bottle
Size Range
Outside Diameter from 13 mm to 37 mm (approximately 0.5” to 1.5”)
Overall Length from 29.5 mm to 65 mm (approximately 1.16” to 2.5”)
Power Ratings:
100-120 V~, 50/60 Hz, 8 amps maximum, or
220-240 V~, 50/60 Hz, 4 amps maximum
Environmental
Requirements:
5 to 40 °C, 0 to 80% RH, non-condensing, indoor use. Optimum results
are obtained from 20 to 40 °C.
Heating Range:
25 °C to 275 °C, electronically controlled
Heater Control:
Temperature controlled to
±
1°
C
of set point
Lower Detection
Limit:
0.1 micrograms
Special Service
Carrier Gas:
Dry nitrogen or dry air (-40 °C dew point, or lower is suggested) at 17 to
22 psi. (User supplied)
Rear Panel
Connections:
Parallel printer port (PC standard)
9 pin RS-232 (9600,N,8,1)
9 pin Balance Comm. (proprietary protocol and cable)
Power cable receptacle with RFI filter
Carrier gas input barb fitting
Carrier gas outlet port - used for test only
Side Panel
Connections:
PC keyboard DIN socket
Resolution:
0.1 micrograms, 1 ppm, 0.0001%
Repeatability:
Depends on sample properties and capillary tube technique, typically CV
is less than 10% for moisture levels above .1% and 15% for moisture
levels below .1%
Automatic Test
Ending Method:
Rate Threshold, user adjustable
Time, user adjustable
Prediction
Time then Rate, user adjustable
Certifications
US and Canadian Underwriters Laboratory / European Communities CE
Arizona Instrument LLC is an ISO9001 Registered Company