11 Disassembly
xFUME™ ADVANCED HP 230V – CSA
11 Disassembly
CAUTION
Risk of injury due to unexpected start
If power is supplied during maintenance, cleaning or disassembly, rotating parts can start running
unexpectedly and lead to injuries from cuts.
► Switch off the device.
► Disconnect all electrical connections.
1
Disconnect the compressed air supply.
2
Remove the current clamp from the cable
assembly.
3
Remove the extraction hose(s).
4
Loosen the bottom clamp on both sides. Loosen
the side clamps on both sides and remove the
housing.
5
Loosen the castors.