10 Faults and troubleshooting
xFUME™ ADVANCED HP 230V – CSA
10 Faults and troubleshooting
► Observe the documentation for the welding components.
► Contact your retailer or ABICOR BINZEL in the event of questions or problems.
WARNING
Health risk caused by inhaling harmful dust
The device contains harmful dust that can collect on surfaces and penetrate the ambient air as of the first
use. It can damage the respiratory tract when inhaled.
► Check and wear your personal protective equipment.
► Use the device only in rooms with sufficient ventilation.
► Ensure that all seals on the device are free from dirt and debris.
► The provided filtration system must be used when operating the device.
► The dust collecting drawer must be closed when operating the device.
► Do not open the dust collecting drawer until at least one minute has passed since the device was
switched off.
► Keep the device closed during operation and during the cleaning process.
► Immediately remove dust deposits from the environment with a dust class H industrial vacuum cleaner
or a damp cloth.
Tab. 3
Faults and troubleshooting
Fault
Cause
Troubleshooting
Extraction volume too low.
Filter elements saturated.
► Replace the filter cartridges.
9.3 Replacing filter cartridges on
page EN
Dust collecting drawer not properly sealed.
► Check and install correctly.
9.2 Emptying the dust collecting drawer
on page EN
Extraction hose blocked.
► Clean the extraction hose.
Extraction hose defective.
► Replace the extraction hose.
6.1 Attaching the extraction hose on
page EN
The quick lock is not mounted correctly.
► Mount the quick lock correctly.
The star screws are not mounted correctly.
► Tighten the star screws by hand.
External extraction system
does not start.
The power supply is faulty.
► Check and replace as needed, or contact
customer service.
Electrical components defective.
Automatic mode, current clamp is not mounted
correctly.
► Mount the current clamp properly.
6.2 Mounting the current clamp on
page EN
Dust escapes from the dust
collecting drawer.
Dust collecting drawer not properly sealed.
► Check and install correctly.
9.2 Emptying the dust collecting drawer
on page EN
Dust collecting drawer full.
► Empty the dust collecting drawer.
9.2 Emptying the dust collecting drawer
on page EN
The quick lock is not mounted correctly.
► Mount the quick lock correctly.
The star screws are not mounted correctly.
► Tighten the star screws by hand.