9 Maintenance and cleaning
EN
-
23
9.4 Replacing the turbines
WARNING
Electric shock due to electronic component damage
When replacing carbon brushes and turbines, electrical connections must be disconnected and
reconnected. Fatal electric shock may occur if electronic components become damaged or improperly
uninstalled in the process.
► The carbon brushes and turbines should be replaced only by a qualified electrician.
1
Remove the upper screws (4×) and the cover.
2
Remove the screws (2× each) and the turbine
covers.
3
Release the grounding cable from the terminal
clamps.
4
Remove the electrical flat plug.
5
Remove the turbines.
6
Insert the new turbines. When doing so, fit the
turbines centrally on the base.
7
Dispose of the turbines in accordance with local
regulations.
8
Reverse the steps above to reassemble the system.