EN - 13
PP Plus 36D/401D
5 Handle operating elements
The required contact pressure is pre-set via the pressure adjustment knob
is readjusted during the welding process.
5 Handle operating elements
Using a standard welding torch, the two-cycle mode of the trigger can be
activated. Further operating modes and handle modules depend on the
corresponding welding power supply and must be ordered separately.
5.1 2-cycle function of the trigger
1
Press the trigger on the handle and keep it pressed = welding is started.
2
Release the trigger = welding is stopped.
6 Putting into operation
1
Open the shielding gas cylinder.
2
Switch on the power supply.
3
Set the welding parameters.
4
Start welding.
7 Putting out of operation
1
Stop welding.
2
Wait until the shielding gas flow has subsided and then switch off the power
supply.
NOTE
• As the MIG/MAG welding torches are integrated into a welding system,
the operating instructions of the welding components, such as the
welding power supply, must be observed during operation.
NOTE
• Hose assemblies containing PVC hoses will start leaking if the return
coolant temperature is exceeded. Make sure not to exceed a return
coolant temperature of 60°C.
NOTE
• Liquid-cooled cable assemblies may start leaking if overheated. This is
why the cooling unit should continue running for approx. 5 min. after
welding.