EN - 12
4 Putting into operation
PP Plus 36D/401D
4.8 Feeding in the wire
1
Insert the wire in the wire feeder as specified by the manufacturer.
2
Open the housing cover
at the handle.
3
Unscrew the clamp clip
by pressing the pressure adjustment knob
upward and swivel it out laterally.
4
Press the "Current free wire feed" trigger at the wire feeder until the wire
comes out of the contact tip.
5
Lock the clamp clip
1
Housing cover
2
Knurled screw
3
Clamp clip
4
Pressure adjustment knob
5
Wire feed roll support
6
Wire feed roll
7
Seat
Fig. 7
Feeding in the wire
1
2
3
4
5
6
7
NOTE
• Each time the wire is changed, make sure that the cutting point is free of
burrs.
• Make sure that the wire feed roll complies with the diameter of the
inserted wire electrode.