background image

Step 5 – Fasten the Threaded Adapter to the Bypass

                                                                     

1. 

Lubricate the ‘o’-ring found 

on the threaded adapter.

 

2. 

 Fasten the 2 nuts to the 

bypass by turning nuts 

clockwise.

Step 4 – Connect Bypass to Fleck Valve

1.

  Apply silicone lube to the 2 ‘o’-rings 

on the bypass valve. Once applied, slide 

bypass valve onto Fleck valve.  

2.

  Fasten the bypass vavle to the Fleck 

valve.  Hand tighten each valve nut 

clockwise.

Valve & Bypass Assembly

Step 6 – Attach Drain Line to Fleck Valve

1. 

Locate drain line elbow

 

2. 

Tape the threaded connection point 

with 3-4 wraps of Teflon tape.  Install 

provided plastic barbed fitting to this 

point.

3. 

Install drain line 

(not included) 

to this 

barbed fitting.  Secure with a stainless 

hose clamp 

(not included).

  Drain line should 

extend to a main drain to dispose of 

waste water.

Make Your Connections

Summary of Contents for Fleck 5810

Page 1: ...Elite High Flow Water Softener System Fleck 5810 Written by 602abcWATER ...

Page 2: ...ank with well safety float and 3 8 brine line 1 Fleck 5810 xtr2 touchscreen digital metered valve 1 Set of 1 threaded adapters 1 Bypass valve 1 Blue bag with small install kit lubricant sanitizer Not included but required Salt Teflon tape fittings to connect softener to your plumbing I D 5 8 O D rigid drain line Be sure to visit our website and our Youtube channel for installation resources to ass...

Page 3: ... locate 2 Attach the top basket to the bottom of the Fleck 5600sxt valve Insert large end of basket into groove and turn clockwise into locking position 3 Apply a thin layer of lubricant to large O ring located outside of threads 4 Connect the Fleck valve to the mineral tank Be sure to carefully line up the top basket to the mineral tank s distributor tube 5 The distributor tube should fit inside ...

Page 4: ...Fleck valve 2 Fasten the bypass vavle to the Fleck valve Hand tighten each valve nut clockwise Valve Bypass Assembly Step 6 Attach Drain Line to Fleck Valve 1 Locate drain line elbow 2 Tape the threaded connection point with 3 4 wraps of Teflon tape Install provided plastic barbed fitting to this point 3 Install drain line not included to this barbed fitting Secure with a stainless hose clamp not ...

Page 5: ... to side wall of brine tank using the supplied white overflow elbow plastic nut Step 9 Connect Brine Line to Safety Float You will receive 1 of 2 types of safety floats One is a compres sion fitting connection and the other is a push to connect fitting The compression fitting requires you to losen the nut prior to in serting the brine line Once the brine line is inserted fasten the compression nut...

Page 6: ...ectors available Step 11 Connect to Water Softener to Power Source 1 Plug in the Fleck 5810 to a power receptacle Your power source should be less than 9 6 feet in distance from the Fleck valve 2 Crack open bypass valves IN OUT sides to begin filling tank You will hear water filling After a few minutes you will hear it quiet down At this point you can open valves all the way 4 Find nearest faucet ...

Page 7: ...Hardness 3 Day Override DO We suggest and set your DO to 14 28 days 3 6 people vs 1 2 people Touch the button to adjust this settting to your preference Touch the Check to confirm and close 4 Regeneration Time RT We suggest and set your RT to 2 a m Touch the button to adjust this setting to your preference Touch the Check to confirm and close 5 Hardness H We set your hardness to 20 grains You can ...

Page 8: ...or troubleshooting of the valve or residential plumbing Please contact your local water treatment professional with questions or concerns about state and local codes This manual can be found on our website Icons That Appear In This Manual Failure to follow this instruction can result in personal injury or damage to the equipment NOTE This will make the process easier if followed General Warnings T...

Reviews: