FEP630, FEH630
ELECTROMAGNETIC FLOWMETER | OI/FEP630/FEH630-EN REV. D
9
Transmitter
1
Dual-compartment transmitter housing
2
Single-compartment transmitter housing
Figure 3: Designs
Transmitter
Model
FET632
Housing
Integral mount design, remote mount design
IP rating
IP 65 / IP 67 / NEMA 4X
Cable length
Maximum 200 m (656 ft), remote mount design only
Power supply
100 to 240 V AC (
−
15 / +10 %) 50 / 60 Hz, 16.8 to 30 V DC
Outputs
Current output: 4 to 20 mA active or passive (can be configured on-site)
Digital output 1: passive, configurable as pulse, frequency or switch output
Digital output 2: passive, configurable as pulse or switch output
Additional outputs
The transmitter has two slots which can be used to insert plug-in cards to extend the outputs.
The following plug-in cards are available:
• Current output (passive)
• Digital output (passive)
• Digital input (passive):
• 24 V DC power supply for active outputs
Communication
Standard: HART® 7.1
Option: PROFIBUS DP® / Modbus®
Approvals
Explosion protection (in preparation)
ATEX / IECEx Zone 1, 2, 21, 22
FM / cFM Cl 1 Div 1, Cl 1 Div 2
Additional approvals
At www.abb.com/flow or on request.