FEP630, FEH630
ELECTROMAGNETIC FLOWMETER | OI/FEP630/FEH630-EN REV. D
117
Error no. / Range Error text
Current output
Digital output
Pulse output
LCD display
Error maskable?
S047.015 /
operation
Pulse output is cut off.
Wrong config. Check pulse out
configuration.
Current value - no
change.
Current value - no
change.
Largest possible
pulse rate
Current value - no
change.
Menu ‘...Group
Masking’.
S046.000 /
operation
Mass flowrate exceeds limits.
Check flowrate and alarm limits.
Current value - no
change.
Alarm, if DO as ‘Qm
Massflow Max’ Or
‘Qm Massflow Min’
is configured.
Current value - no
change.
Current value - no
change.
Menu ‘...Group
Masking’.
S044.001 /
operation
Volume flowrate exceeds limits.
Check flowrate and alarm limits.
Current value - no
change.
Alarm, if DO as ‘Qv
Volumeflow Max’ Or
‘Qv Volumeflow Min’
is configured.
Current value - no
change.
Current value - no
change.
Menu ‘...Group
Masking’.
S041.034 /
electronics
DC feedback regulation.
Check conditions of application.
Call service.
4 mA (0 % flow)
No Answer.
0 Hz
0 %
Menu ‘...Group
Masking’.
S040.031 /
electronics
Coil Inductance alarm.
Call service.
Current value - no
change.
No Answer.
Current value - no
change.
Current value - no
change.
Menu ‘...Group
Masking’.
M038.009 /
electronics
Sensor memory defective.
Mem. or connect. defective.
Replace memory.
Current value - no
change.
No Answer.
Current value - no
change.
Current value - no
change.
Menu ‘...Group
Masking’.
M037.014 /
Electronics
NV chips defect on
Motherboard.
Defective MB. Replace MB. Call
Service.
M032.022 / Config. Curr.Out 31 / 32 not calibrated.
Call Service.
M031.023 / Config. Curr.Out V1 / V2 not calibrated.
Replace Current Option Card.
Call Service.
Current value - no
change.
Current value - no
change.
Current value - no
change.
Current value - no
change.
Menu ‘...Group
Masking’.
M030.024 /
Config.
Curr.Out 31 / 32 not calibrated.
Call Service.
M028.007 /
Config.
Display value is < 1600 h at
Qmax.
Change mass Unit or vol. Unit
for Totalizer.
Current value - no
change.
No Answer.
Current value - no
change.
Current value - no
change.
Menu ‘...Group
Masking’.
M026.004 /
Config.
Maintenance interval is reached.
Perform maintenance.
M024.008 /
Config.
Device not calibrated.
Call Service.
High Alarm or Low
Alarm, depending on
parameter ‘Curr.Out
at Alarm’.
Current value - no
change.
Current value - no
change.
Current value - no
change.
Menu '...Group
Masking’.
M020.027 /
Electronics
Communicat. Card not
responding
Current value - no
change.
Current value - no
change.
Current value - no
change.
Current value - no
change.
Menu ‘...Group
Masking’.
Change from one to two columns