![ABB Navigator 540 Instruction Manual Download Page 22](http://html.mh-extra.com/html/abb/navigator-540/navigator-540_instruction-manual_4465022.webp)
22
COM/AWT540/PB–EN Rev. C
| Navigator 540 | Transmitter
Stream 1 – Concentration
40
40
Simple
Float
4
D
R
Two-stream
Stream 1 – Temperature
40
41
Simple
Float
4
D
R
Stream 2 – Concentration
40
42
Simple
Float
4
D
R
Stream 2 – Temperature
40
43
Simple
Float
4
D
R
Raw signal
40
44
Simple
Float
4
D
R
Stream 1 – Flow rate
40
45
Simple
Float
4
D
R
Stream 2 – Flow rate
40
46
Simple
Float
4
D
R
Active calibration slope
40
47
Simple
Float
4
D
R
Active calibration offset
40
48
Simple
Float
4
D
R
Last calibration slope
40
49
Simple
Float
4
D
R
Last calibration offset
40
50
Simple
Float
4
D
R
Stream 1 – Concentration
40
51
Simple
Float
4
D
R
Three-stream
Stream 1 – Temperature
40
52
Simple
Float
4
D
R
Stream 2 – Concentration
40
53
Simple
Float
4
D
R
Stream 2 – Temperature
40
54
Simple
Float
4
D
R
Stream 3 – Concentration
40
55
Simple
Float
4
D
R
Stream 3 – Temperature
40
56
Simple
Float
4
D
R
Raw signal
40
57
Simple
Float
4
D
R
Stream 1 – Flow rate
40
58
Simple
Float
4
D
R
Stream 2 – Flow rate
40
59
Simple
Float
4
D
R
Stream 3 – Flow rate
40
60
Simple
Float
4
D
R
Active calibration slope
40
61
Simple
Float
4
D
R
Active calibration offset
40
62
Simple
Float
4
D
R
Last calibration slope
40
63
Simple
Float
4
D
R
Last calibration offset
40
64
Simple
Float
4
D
R
Description
Slot
Index
Object type
Data type
Bytes
Store
Access
Notes
Sensor 1 – Concentration range high
40
65
Simple
Float
4
C
R
See engineering ranges
Sensor 1 – Concentration range low
40
66
Simple
Float
4
C
R
Sensor 2 – Concentration range high
40
67
Simple
Float
4
C
R
Sensor 2 – Concentration range low
40
68
Simple
Float
4
C
R
Sensor 3 – Concentration range high
40
69
Simple
Float
4
C
R
Sensor 3 – Concentration range low
40
70
Simple
Float
4
C
R
Sensor 4 – Concentration range high
40
71
Simple
Float
4
C
R
Sensor 4 – Concentration range low
40
72
Simple
Float
4
C
R
Sensor 1 – Temperature range high
40
73
Simple
Float
4
C
R
Sensor 1 – Temperature range low
40
74
Simple
Float
4
C
R
Sensor 2 – Temperature range high
40
75
Simple
Float
4
C
R
Sensor 2 – Temperature range low
40
76
Simple
Float
4
C
R
Sensor 3 – Temperature range high
40
77
Simple
Float
4
C
R
Sensor 3 – Temperature range low
40
78
Simple
Float
4
C
R
Sensor 4 – Temperature range high
40
79
Simple
Float
4
C
R
Sensor 4 – Temperature range low
40
80
Simple
Float
4
C
R
Table A.12: Measurement range limits
Description
Slot
Index
Object type
Data type
Bytes
Store
Access
Notes
Table A.11: Sensor signals view (continued)