8 Technical data
Manufacturer
Address
ABB JOKAB SAFETY
Varlabergsvägen 11
434 39 Kungsbacka
Voltage supply
Operating voltage
Electromagnet: +24 VDC ±15 %
Power consumption
Electromagnet: 7 W (350 mA at +24 VDC)
Standby 1 W (40mA at 24V)
Information output: Max 20 mA
Important
! Cable dimensioning should be checked when connecting several units in series. Standard
cables from ABB/Jokab Safety have a cross sectional area of 0.34 mm
2
. Magne does not cause
any power surge when locking is activated.
General
Ambient temperature
Operation: -
20…+50°C
Storage -
20…+70°C
Humidity
35-85 % (without ice formation or condensation)
EMC
EN 60947-5-3
Holding force
1500 N (on correct installation)
0 V: 0 N
Anchor plate permanent magnet: 30 N (Anchor plate 32B)
Locking function
Electromagnet (M)
Electrical data
Information output
Current limited 20 mA (non-failsafe).
Magne 4…. :
Transponder frequency
4MHz
Activation delay on connecting
<2s
Max connection frequency
0.3Hz
Voltage drop outputs
VCC -2.5V
Reaction time on activation
<150ms
Reaction time on stopping
First unit: <30ms
For each additional unit: <5ms
Safe unlocking distance
25 mm
Safe usage distance
7 mm
Useful life
20 years
OSSD
OSSD output
Max 50mA (current limited)
Reaction time on stopping
First unit <30ms
For each additional unit < 5ms