2TLC172315M0201, rev K
14
www.abb.com/jokabsafety
Monday, May 07, 2018 10:51:13 AM
5 Installation and maintenance
Maximum installation tolerance between electromagnet and anchor plate is ±5 mm lengthways to Magne and
±3 mm sideways. Available fittings for closing doors are designed for 5
–15 mm door gap Dimensions for installation
of a sliding door as drawing below.
The anchor plate is mounted with 2 X M8 bolts with cellular rubber between the anchor plate and door. The cellular
rubber enables the anchor plate to adjust to Magne. The cellular rubber should not be compressed to a thickness
less than 8 mm. Choose suitable bolt that reaches the bottom of the anchor plate hole allowing sufficient play in the
cellular rubber to ensure anchor plate movement. Recommended torque is 7 ±2 Nm.
Installation instructions included with the respective installation kit.
Important
! All dimensions given in millimeters.
Positioning of Eva
Installation directions
Please carefully follow the instructions below to avoid personal injuries or damage to the unit.
Caution
After installation, check that the surfaces of the magnet and anchor plate are flush and
parallel such that full contact is obtained with the door is closed.
6
0
1
8
±
5
69 ±5
Magne 1A
Sliding door
Fence
Installation tolerances (general)
Installation tolerances (sliding door with Magne 3 and JSM
D23)
Magne