4
Software WIN-PC for Intrusion Alarm Panel L240
3
Connection points
to the panel L240
3.1
Login of the interface module
3.2
Serial connection with
L208/V24
The connection of the L240 to the PC is implemented either via a serial
interface with the Interface Module L208/V.24 or via a LAN network with
the IP Interface L240/IP.
The modules L208/V.24 or L240/IP (SM) are automatically detected in the
L240 factory default state. Log on and off is not necessary.
How to verify log on:
• In the Engineer level (see “Note”), use button 8 to recall the menu
“8=Edit”.
• Select the function “01=Hardware” here.
• Log on has been successful if the interface modules indicate that “2”
(SM-2) has been connected.
System Size
SM-2
Note:
A detailed introduction into the operating structure of the panel L240
can be found in the manual “Installation Commissioning Operation of the
System L240”.
The Engineer level can be accessed from the base display
“Date Int Unset” as follows:
• Button 4 for entering the User PIN
(“4=Input PIN”)
• Button 11 for entering the Engineer PIN
(“11=Input Eng.PIN”)
(Acknowledge the entry of the respective PIN with the “Return” button.)
The interface module is integrated into a white plastic enclosure.
It is connected to the wall with 3 screws.
Only two connection points are available:
On the circuit board, the 4-core XIB-Bus cable should be connected to
the cond/-/A/B. A 9-pole SUB-D connector protrudes from the
enclosure to which a null-modem cable is directly connected to the PC.
The plug-in jumper LK1 can be used for bypassing the panel tamper
contacts to suppress the tampering alarm during commissioning
(otherwise tamper alarm).
Jumper LK1 must be removed again after commissioning.