4 Repair
4.3.3. Replacement of cable harness, Cleanroom
3HAC026876-001 Revision: C
212
© Copyri
ght
200
6-2008 ABB.
All rights reserved.
14. Open the gripping clamp on the lower bracket and
remove the cable harness.
xx0800000053
Parts:
•
A: Gripping clamp
15. Remove the velcro straps on the side bracket,
balancing device.
xx0800000052
Parts:
•
A: Velcro starps
•
B: Cable harness
16. Open the gripping clamp on the lower arm and
remove the cable harness.
xx0800000051
Parts:
•
A: Gripping clamps
17. Continue removal of the upper end of the cable
harness.
Action
Note
Continued
Continues on next page