Flange sealings and static sealings
The following procedure describes how to fit flange sealings and static sealings.
Action
Check the flange surfaces. They must be even and free from pores.
1
It is easy to check flatness using a gauge on the fastened joint (without sealing com-
pound).
If the flange surfaces are defective, the parts may not be used because leakage could
occur.
Clean the surfaces properly in accordance with the recommendations of ABB.
2
Distribute the sealing compound evenly over the surface, preferably with a brush.
3
Tighten the screws evenly when fastening the flange joint.
4
O-rings
The following procedure describes how to fit o-rings.
Note
Action
Ensure that the correct o-ring size is used.
1
Defective o-rings, including damaged
or deformed o-rings, may not be used.
Check the o-ring for surface defects, burrs,
shape accuracy, or deformation.
2
Check the o-ring grooves.
3
The grooves must be geometrically correct and
should be free of pores and contamination.
Lubricate the o-ring with grease.
4
Tighten the screws evenly while assembling.
5
Check that the o-ring is not squashed outside
the o-ring groove.
6
Make sure that no grease is left on the robot
surface.
7
144
Product manual - IRB 1300
3HAC070390-001 Revision: G
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.2.1 Mounting instructions for sealings
Continued
Summary of Contents for IRB 1300
Page 1: ...ROBOTICS Product manual IRB 1300 ...
Page 8: ...This page is intentionally left blank ...
Page 36: ...This page is intentionally left blank ...
Page 100: ...This page is intentionally left blank ...
Page 746: ...This page is intentionally left blank ...
Page 762: ...This page is intentionally left blank ...
Page 764: ...This page is intentionally left blank ...
Page 768: ......
Page 769: ......