Note
Action
xx2000001569
Route the cable package through the lower arm
support and up into the housing.
CAUTION
Make sure that no cables or hoses are twisted or
strained. Reroute if necessary.
4
Reconnecting the axis-2 and -3 motor connectors
Note
Action
For robots with protection type Clean Room:
1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
xx2000001551
Insert the male header of the motor connectors
to the connector plate.
2
xx2000001549
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
3
Continues on next page
Product manual - IRB 1300
665
3HAC070390-001 Revision: G
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.7.3 Replacing the axis-3 gearbox
Continued