Installation and maintenance guide
1ZSC000563-AAX EN, REV. A, 2019-03-21
25
5.
Remove the transformer cover (13) from the
transformer (11).
G004186
6.
Install the winding cables to the bottom contact.
CAUTION!
Make sure that there is no tension in
the windig cables. Tension in the
winding cables will cause damage to
the bottom contact.
G003001
Torque
68 ±6 Nm
7.
Only for the GSC 200/300/400/450S. Make sure
the compensating device (14) is still in the
bushing.
G004224
8.
Lift the bushing above the opening on the transformer.