Chapter 2 - Start-Up Instructions
DCS 600 Operating Instructions
IV F
2 - 5
•
Programmable values (can be changed for monitoring of other signals)
Cyclic transmission time for the first three programmable values is every 2 ms, for all
other values every 8 ms:
Cyclic transmission
Enter pa-
Cyclic trans-
Default
from
-->
to
rameter in
mission time
AMC
--> CON-2
95.01
2 ms
3.11 CURRENT REF
AMC
--> CON-2
95.02
2 ms
45.01 FLUX REF
AMC
--> CON-2
95.03
2 ms
45.03 EMF REF
AMC
--> CON-2
95.04
8 ms
0
AMC
--> CON-2
95.05
8 ms
0
AMC
--> CON-2
95.06
8 ms
0
AMC
--> CON-2
95.07
8 ms
0
AMC
--> CON-2
95.08
8 ms
0
AMC
--> CON-2
95.09
8 ms
0
AMC
--> CON-2
95.10
8 ms
0
AMC
--> CON-2
95.11
8 ms
0
AMC
--> CON-2
95.12
8 ms
0
AMC
--> CON-2
95.13
8 ms
0
CON-2 --> AMC
94.01
2 ms
3.13 ARM ALPHA
CON-2 --> AMC
94.02
2 ms
1.15 CONV CUR
CON-2 --> AMC
94.03
2 ms
3.12 CUR REF3
CON-2 --> AMC
94.04
8 ms
1.11 RL MAINS VOLT ACT
CON-2 --> AMC
94.05
8 ms
1.13 RL ARM VOLT ACT
CON-2 --> AMC
94.06
8 ms
1.28 LOAD CUR ACT FILT
CON-2 --> AMC
94.07
8 ms
1.17 RL EMF VOLT ACT
CON-2 --> AMC
94.08
8 ms
1.24 HEATSINK TEMP
CON-2 --> AMC
94.09
8 ms
1.20 MOT1 CALC TEMP
CON-2 --> AMC
94.10
8 ms
3.17 FIELD CUR REF M1
CON-2 --> AMC
94.11
8 ms
3.19 REL FIELD CUR M1
For example:
Display of actual field current value 3.19 in 8 ms
⇒
94.11 = 3.19.
Then call for display of Parameter 3.19.