![ABB CoriolisMaster FCB400 Manual Download Page 70](http://html1.mh-extra.com/html/abb/coriolismaster-fcb400/coriolismaster-fcb400_manual_3662119070.webp)
70
CoriolisMaster FCB400, FCH400
CORIOLIS MASS FLOWMETER | CI/FCB400/FCH400-EN REV. H
… 6 Electrical connections
… Digital communication
Ethernet card status LEDs
The 6 LEDs on the Ethernet card indicate the status of each port and the network.
To enable card status indication in the upper HMI Line, navigate to ‘Display / Display Tag / Ethernet Status’.
A
Port 1
B
Activity 1
C
Port 2
D
Activity 2
E
Module Status (Mod)
F
Network Status (Net)
Figure 62: Ethernet card status LEDs
LED Status
HMI display
Description
A
Port 1
ON
Network connection (link up)
OFF
No network
B
Activity 1
Flashing or ON
Traffic
OFF
No traffic
C
Port 2
ON
Network connection (link up)
OFF
No network
D
Activity 2
Flashing or ON
Traffic
OFF
No traffic
E
Module Status (Mod)
green, ON
Mod showing <G> continously
Device ready for Operation.
Working properly
green, Flashing (1 Hz)
Mod changing between <G> and < >
Standby. Device not configured yet
green/ red, Flashing (1Hz)
Device performs "Power-On" Test
red, Flashing (1 Hz)
Mod changing between <R> and < >
Simple Error, which can be fixed
red, ON
Mod showing <R> continously
Major Error.
Non removable serious error
OFF
Mod showing < > continously
No Power
F
Network Status (Net)
green, ON
Net showing <G> continously
Connected. Device has at least one
established connection
green, Flashing (1 Hz)
Net changing between <G> and < >
No Connection.
Device did not establish any connections,
but was assigned an IP address
green/ red, Flashing (1Hz)
Device performs "Power-On" Test
red, ON
Net showing <R> continously Dublicated IP address. Device has detected
that the device IP address is already in use
OFF
Net showing < > continously
No supply voltage or IP Address.
red, flashing (1 Hz)
Mod changing between <R> and < >
Connection timeout