Pulse Mode
For example:
Pulse / Unit = 50, Pulse Units = l, Totalizer required to increment in m
3
.
Volume unit conversion: 1 l = 0.001 m
3
.
Count Rate =
Volume unit conversion
Pulse / Unit
Count Rate =
0.001
= 0.00002 m
3
/pulse