SEtUP
ContrL
Set Up Control
Control Type
PFMOdE
––––––
Power Failure Mode
MAN.MAN
–––.–
Man/Man Power Fail
AUt.MAN
–––
Auto/Man Power Fail
C-tYPE
––––
Set Up Control Page
Section 4.3.1, Page 36
OP–HI
–––.–
Output High LImit
Control Action
ACtION
–––
SELECt
––––––
Select Controller
OP–LO
––––
Output Low Limit
dFA–PV
––––
dEF–OP
––––
dFA–SP
––––
dEF–SP
––––
dFA–Fb
––––
Default Action PV
Default Output
Default Action SP
Default SP
Default Action PFB
Control Offset
OFFSEt
––.–
SELECt
––––––
Select Controller
Power Fail Enable
AUt_AN
–––
A/M Enable
_r_AdJ
–––
SP–SEL
–––
S.P. Select Enable
SP–AdJ
–––
r–ADJ
–––
Ratio Adjust Enable
PF–INd
–––
Operating Page Set Up
Section 4.4, Page 44
Man. Reset Enab.
S.P Adjust Enable
b–AdJ
–––
Bias Adjust Enable
Set Up Digital
Section 4.5, Page 45
Set Up Digital
Select Controller
A/M Select Source
L/R Select Source
Auto Select Source
Local Select Source
Set Point 1 Source
Rmt Select Source
SEtUP
dIGtAL
SELECt
––––––
A_ SrC
––––––
_AN.SrC
––––––
AUt.SrC
––––––
Lr SrC
––––––
LOC.SrC
––––––
rEM.SrC
––––––
SP1.SrC
––––––
Man Select Source
Set Point 1
SPt–1
––––
Set Point 2 Source
SP2.SrC
––––––
Set Point 2
SPt–2
––––
Configured Output
C–OUt
––––––
Set up Op Page
SEtUP
OP PGE
SEt
POINtS
Set Points
2Nd–SP
––––
Set Points Page
Section 4.1, Page 29
dSPt-x
––––
LSP–HI
––––
rSPtrK
_ _ _ _
dSP–HI
––––
Control Action High
ACtION
h –––
AUt.AUt
––––
Auto/Auto PowerFail
Ht–HI
––––
Heat High LImit
CL– ––
––––
Cool High/Low Limit
rAtIO
–.––
M. Valve Ratio
M. Valve Bias
rGL–t
––––
bIAS
–.––
Valve Page
Section 4.2.3, Page 35
Regulator Travel
Valve Page
VALVE
PAGE
dEAd b
––.–
M. Valve Deadband
Set Point 3 Source
SP3.SrC
––––––
Set Point 3
SPt–3
––––
LSP–LO
––––
LSPt-x
––––
SP–trK
––––––
dSP–LO
––––
rSP–HI
––––
rSP–LO
––––
Set Point High Limit
Set Point Low Limit
Local Set Point
Set Point Tracking
2nd Set Point
Dual S/P High Limit
Dual S/P Low Limit
Dual S/P Value
Remote SP Tracking
Remote S/P High
Remote S/P Low
Set Point Type
OPrtOr
LEVEL
bASIC
CONFIG
AdVNCd
CONFIG
Basic Config
Advanced Config
Operator Level
CONtrL
CONFIG
Control Config
SELECt
––––––
SELECt
––––––
Select Controller
Select Controller
Man/Auto Power Fail
MAN.AUt
––.–
Heat/Cool Control
ACtION
C –––
Control Action Cool
rAtIO
––––
bIAS
––––
------
------
Ratio
Bias
CAStrK
_ _ _ _
CAS–HI
––––
CAS–LO
––––
Cascade SP Tracking
Cascade S/P High
Cascade S/P Low
OP trK
_ _ _ _
Output Tracking
Bargraph Increment
INCMNt
__
4
CONTROL CONFIGURATION LEVEL
Fig. 4.1 Control Configuration Level