Parameters 333
(Visible when an absolute encoder is selected)
Defines the number of bits used in revolution counting with
a multiturn encoder. For example, a setting of 12 bits
would support counting up to 4096 revolutions.
The value is used when parameter
is set to
. When parameter
is set to
, setting
this parameter to a non-zero value activates multiturn data
requesting.
0
0…32
Number of bits used in revolution count.
1 = 1
(Visible when a TTL, TTL+ or HTL is selected)
Activates transient filtering for the encoder (changes in
direction of rotation are ignored above the selected pulse
frequency).
4880 Hz
Change in direction of rotation allowed below 4880 Hz.
0
2440 Hz
Change in direction of rotation allowed below 2440 Hz.
1
1220 Hz
Change in direction of rotation allowed below 1220 Hz.
2
Disabled
Change in direction of rotation allowed at any pulse
frequency.
3
(Visible when parameter
)
Selects the power supply voltage for encoder 1.
0V
Disabled.
0
5V
5 V.
1
24V
24 V.
2
Accepted pulse freq
of encoder 1
(Visible when parameter
)
Defines the maximum pulse frequency of encoder 1.
0 kHz
0…300 kHz
Pulse frequency.
1 = 1 kHz
(Visible when a TTL, TTL+ or HTL is selected)
Selects which encoder cable channels and wires are
monitored for wiring faults.
A, B
A and B.
0
A, B, Z
A, B and Z.
1
A+, A-, B+, B-
A+, A-, B+ and B-.
2
A+, A-, B+, B-, Z+, Z- A+, A-, B+, B-, Z+ and Z-.
3
(Visible when an absolute encoder is selected)
Selects the serial link mode with an EnDat or SSI encoder.
Initial position
Single position transfer mode (initial position).
0
Continuous
Continuous position data transfer mode.
1
Continuous speed
and position
Continuous speed and position data transfer mode. This
setting is intended for EnDat 2.2 encoders without sin/cos
signals.
Note:
This setting requires an FEN-11 interface revision H
or later.
2
No.
Name/Value
Description
Def/
FbEq16
Summary of Contents for ACS880 PCP
Page 1: ...ABB industrial drives Firmware manual ACS880 PCP ESP control program ...
Page 4: ......
Page 28: ...28 PCP ESP control start up ...
Page 30: ...30 Using the control panel ...
Page 94: ...94 Standard programposi features ...
Page 100: ...100 Default control connections ...
Page 360: ...360 Parameters ...
Page 436: ...436 Fault tracing ...
Page 486: ...486 Control chain diagrams ...
Page 492: ...492 Appendix ESP with step up transformer and sine filter ...
Page 494: ...Contact us www abb com drives www abb com drivespartners 3AXD50000016186 Rev B EN 2015 10 27 ...