What to do
Cause
Fault indication/Fault
Check voltage setting.
Chopper voltage setting too low.
Chopper starts to function at
too low a DC voltage.
Check voltage setting.
Chopper voltage setting too high.
Inverter trips on fault 3210 DC
link overvoltage.
Check parameters of all inverters.
Check duty cycle and resistor cooling.
The maximum brake cycle exceeded
or resistor cooling insufficient.
Brake resistor or chopper
overheats.
LEDs
■
Control panel and panel platform/holder LEDs
The ACX-AP-x control panel has a status LED. The control panel mounting platform or
holder has two status LEDs. For their indications, see the following table.
Indication
LED
Location
The unit is functioning normally.
Continuous green
Control panel
Data is transferred between the PC and the unit through the USB
connection of the control panel.
Flickering green
There is an active warning in the unit.
Blinking green
There is an active fault in the unit.
Continuous red
There is a fault that requires the stopping and restarting of the
drive/converter/inverter.
Blinking red
The Bluetooth interface is enabled, in discoverable mode, and
ready for pairing.
Blinking blue (ACS-
AP-W only)
Data is being transferred through the Bluetooth interface of the
control panel.
Flickering blue
(ACS-AP-W only)
There is an active fault in the unit.
Red
Control panel
mounting platform or
holder (with the con-
trol panel removed)
Power supply for the control unit is OK.
Green
■
Control unit LEDs
This table shows the LEDs visible on the BCU-xx control unit.
Indication
Color
LED
Battery voltage of the real-time clock is OK (higher than 2.8 V).
When the LED is not lit,
Green
BATT OK
• battery voltage is below 2.8 V,
• the battery is missing, or
• the control unit is not powered.
Internal voltage OK
Green
PWR OK
The control program indicates that the equipment is faulty. See
the appropriate firmware manual.
Red
FAULT
Writing to SD card in progress.
Yellow
WRITE
60 Fault tracing
Summary of Contents for ACS880-607 Series
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 607 3 phase brake units Hardware manual ...
Page 2: ......
Page 4: ......
Page 8: ...8 ...
Page 12: ...12 ...
Page 30: ...30 ...
Page 32: ...32 ...
Page 36: ...36 ...
Page 44: ...44 ...
Page 54: ...54 ...
Page 62: ...62 ...
Page 66: ...66 Maintenance ...
Page 82: ...Dimension drawing bottom exit 82 Dimension drawings ...
Page 83: ...Dimension drawings 83 ...
Page 84: ...Dimension drawing top exit 84 Dimension drawings ...
Page 85: ... Dimension drawings 85 ...
Page 86: ......