![ABB ACS880-604LC Hardware Manual Download Page 79](http://html.mh-extra.com/html/abb/acs880-604lc/acs880-604lc_hardware-manual_3992079.webp)
Note:
The optical components (transmitter and receiver) on a fiber optic link must be of the same
type.
Plastic optical fiber (POF) cables can be used with both 5 MBd and 10 MBd optical
components. 10 MBd components also enable the use of Hard Clad Silica (HCS®) cables,
which allow longer connection distances thanks to their lower attenuation. HCS® cables
cannot be used with 5 MBd optical components.
The maximum lengths of fiber optic links for POF and HCS® cables are 20 and 200 meters
respectively.
Ambient conditions
The unit is to be used in a heated indoor controlled environment.
Transportation
in protect-
ive package
Storage
in protective
package
Operation
installed for
stationary use
-
-
0 … 2000 m
(0 … 6561.7 ft) no derat-
ing.
Altitude above sea level
For altitudes over 2000 m
(6561.7 ft), contact ABB.
-40 … +70 °C
-40 … +70 °C
0 … +55 °C
(+32 … +131 °F), no con-
densation allowed.
Air temperature
(-40 … +158 °F)
(-40 … +158 °F)
Maximum 95%, no con-
densation allowed
Maximum 95%, no con-
densation allowed
Maximum 95%, no con-
densation allowed
Relative humidity
No condensation allowed. Maximum allowed relative humidity is 60% in the presence
of corrosive gases.
IEC 60721-3-2
IEC 60721-3-1
IEC/EN 60721-3-3:2002:
Classification of environ-
mental conditions - Part 3-
3: Classification of groups
of environmental paramet-
ers and their severities -
Stationary use of weather
protected locations
Contamination
Class 2C2
Class 1C2
Class 3C2
Chemical gases
Class 2S2
Class 1S3 (packing must
support this, otherwise
1S2)
Class 3S1
Solid particles
No conductive dust al-
lowed.
Technical data 79
Summary of Contents for ACS880-604LC
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 604LC 1 phase brake units as modules Hardware manual ...
Page 2: ......
Page 4: ......
Page 12: ...12 ...
Page 20: ...20 ...
Page 33: ...Overview of kits Mechanical installation 33 10 ...
Page 34: ...Stage 1 Installation of common parts 34 Mechanical installation ...
Page 35: ...Stage 2 Installation of mounting plate Mechanical installation 35 10 ...
Page 36: ...Stage 3 Installation of cooling components 36 Mechanical installation ...
Page 37: ...Stage 4 Installation of brake module and attenuator Mechanical installation 37 10 ...
Page 40: ...40 ...
Page 58: ...58 ...
Page 64: ...64 ...
Page 82: ...82 ...
Page 84: ...Brake chopper module NBRW 669 84 Dimension drawings ...
Page 85: ...Attenuator Dimension drawings 85 ...
Page 86: ...Brake resistor 234 300 1320 Ø 7 345 R R 1270 86 Dimension drawings ...
Page 88: ...88 ...
Page 102: ......