![ABB ACS880-604LC Hardware Manual Download Page 44](http://html.mh-extra.com/html/abb/acs880-604lc/acs880-604lc_hardware-manual_3992044.webp)
Selecting the voltage
Before wiring the brake unit, select the voltage level as follows:
1.
Remove the chopper front panel by undoing the four screws at the top and bottom of
the panel.
2.
Set the voltage selection jumper on the chopper control board (see
)
to the appropriate voltage as shown below.
FIB
E
R
23
0 V
40
0 V
>5
00
V
Drive supply voltage 380…415 V
FIB
E
R
23
0 V
40
0 V
>5
00
V
Drive supply voltage 440…500 V
F
IBER
230 V
400 V
>5
00
V
Drive supply voltage 525…690 V
Note:
In follower choppers, you must set the voltage to FIBER as shown in section
below.
WARNING!
An incorrect jumper setting or missing jumper may cause brake chopper malfunction
or damage to the chopper or resistor.
44 Electrical installation
Summary of Contents for ACS880-604LC
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 604LC 1 phase brake units as modules Hardware manual ...
Page 2: ......
Page 4: ......
Page 12: ...12 ...
Page 20: ...20 ...
Page 33: ...Overview of kits Mechanical installation 33 10 ...
Page 34: ...Stage 1 Installation of common parts 34 Mechanical installation ...
Page 35: ...Stage 2 Installation of mounting plate Mechanical installation 35 10 ...
Page 36: ...Stage 3 Installation of cooling components 36 Mechanical installation ...
Page 37: ...Stage 4 Installation of brake module and attenuator Mechanical installation 37 10 ...
Page 40: ...40 ...
Page 58: ...58 ...
Page 64: ...64 ...
Page 82: ...82 ...
Page 84: ...Brake chopper module NBRW 669 84 Dimension drawings ...
Page 85: ...Attenuator Dimension drawings 85 ...
Page 86: ...Brake resistor 234 300 1320 Ø 7 345 R R 1270 86 Dimension drawings ...
Page 88: ...88 ...
Page 102: ......