Years from start-up
Component
…
12
11
10
9
8
7
6
5
4
3
2
1
Cooling fans
R
R
R8i 230 VAC
R
R
R8i 115 VAC
Coolant
R
R
Coolant draining and refill
Batteries
R
Control panel battery
R
R
Control unit battery
Connections and environment
P
P
P
P
P
P
P
P
P
P
P
P
P
Quality of supply voltage
Spare parts
I
I
I
I
I
I
I
I
I
I
I
I
I
Spare part stock
P
P
P
P
P
P
P
P
P
P
P
P
P
Reforming DC circuit capacitors
(spare modules and spare capa-
citors)
Other useful tasks
I
I
I
I
I
I
I
I
I
I
I
I
I
Tightness of terminals
I
I
I
I
I
I
I
I
I
I
I
I
I
Dustiness, corrosion and temper-
ature
I
I
I
I
I
I
I
I
I
I
I
I
I
Cooling liquid pipe connections
P
P
P
P
P
P
P
P
P
P
P
P
P
Coolant antifreeze concentration
P
P
P
P
P
P
Inspection of coolant quality
Symbols
Inspection
(visual inspection and maintenance action if needed)
I
Performance
of on/off-site work (commissioning, tests, measurements or other work)
P
Replacement
R
Maintenance and component replacement intervals are based on the assumption that the
equipment is operated within the specified ratings and ambient conditions. ABB recommends
annual drive inspections to ensure the highest reliability and optimum performance.
Note:
Long term operation near the specified maximum ratings or ambient conditions may require
shorter maintenance intervals for certain components. Consult your local ABB Service
representative for additional maintenance recommendations.
Maintenance timers and counters
The control program has maintenance timers and counters that can be configured to generate
a warning when a pre-defined limit is reached. Each timer/counter can be set to monitor
any parameter. This feature is especially useful as a service reminder. For more information,
see the firmware manual.
70 Maintenance
Summary of Contents for ACS880-1607LC
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 1607LC DC DC converter units Hardware manual ...
Page 2: ......
Page 4: ......
Page 12: ...12 ...
Page 32: ...32 ...
Page 38: ...38 ...
Page 60: ...60 ...
Page 80: ...80 ...
Page 90: ...90 ...
Page 102: ...Unit with 1 R8i converter module 102 Dimension drawings ...
Page 103: ...Dimension drawings 103 ...
Page 104: ...Location and size of energy storage connection terminals 104 Dimension drawings ...